To review the open zones click
door or window sensor) will be displayed. To fix the open zone, locate the sensor and secure it (close the door
or window) – see "device locator" below. Each click of
It is highly recommended to fix the open zone(s), thus restoring the system to the state of "ready to arm". If you
do not know how to do this, consult your installer.
Note: To quit at any stage and to revert to the "READY" display, click
Device Locator: The WP8010/WP8030 system has a powerful device locator that helps you to identify open or
troubled devices indicated on the LCD display. While the LCD displays an open or faulty device, the LED on the
respective deice flashes indicating "it's me". The "it's me" indication will appear on the device within max. 16
seconds and will last for as long as the LCD displays the device.
Zone Bypass Scheme
Bypassing permits arming only part of the system and at the same time allowing free movement of people within
certain zones when the system is armed. It is also used to temporarily remove from service faulty zones that
require repair work or to deactivate a sensor if, for example, you are decorating a room.
You can set the Zone Bypass Scheme i.e. to scroll through the list of registered (enrolled) sensors to your
WP8010/WP8030 system and to Bypass (deactivate) faulty or disturbed sensors (either READY or NOT-
READY) or to Clear (reactivate) BYPASSED zones (sensors).
Once you have set a Bypass Scheme you can use the following 3 options:
To quickly clear a bypassed zone i.e. to reactivate the bypassed zone – refer to
of the WP8010/WP8030
To quickly review the bypassed zones – refer to
Guide.
To repeat (recall) the last used zone bypassing scheme – refer to Chapter 6, section B.3 of the
WP8010/WP8030User's Guide.
Event Notification by Telephone
The WP8010/WP8030 can be programmed for selective notification of event messages to private telephone
subscribers – refer to
Chapter 6, section B.11 of the WP8010/WP8030G2
WP8010control panels
In case of alarm the following voice signal will be sent to private telephones upon event reporting:
*
FIRE: ON - ON - ON - pause....
**
BURGLAR: ON continuously (
*** EMERGENCY: 2-tone siren; like an ambulance.
To stop the alarm notification – press "2" on your telephone keyboard. The alarm sound will stop immediately.
WP8030control panels
When the called party answers a call initiated by the WP8030, he will hear a verbal message composed of the
"house identity" and the type of event that occurred.
The called party can acknowledge the message by pressing a key on the telephone keypad, as follows.
Command
Acknowledge only: The WP8010/WP8030
reported.
Acknowledge and listen-in: The protected site is "bugged" for sound for 50 seconds. The called party
may prolong the listening session by pressing [3] again before the WP8010/WP8030 disengages the
line, or by pressing [1] to speak.
Acknowledge and speak out: The called party may speak for 50 seconds to whoever is in the
protected site. The called party may prolong the "speak out" session by pressing [1] again before the
WP8010/WP8030 disengages the line, or by pressing [3] to listen.
Acknowledge and 2-way conversation: You and the called party can speak and listen without any
necessity to switch the system from "listen-in" to "speak-out" and vice versa for 50 sec. (extendable).
Acknowledge and request a status report: The WP8010/WP8030 will issue a verbal report of system
status. For example:
[Disarm - ready to arm] or [Disarm - back door open] or [Disarm - alarm in memory].
D-306233 CUSDOC PM-10/30 V18 DSC TRIPLE EN INST
. The details and location of the first open zone detector (usually an open
User's Guide.
(- - - - - -
......).
...)
disengages the line and considers the event duly
will display another open zone or trouble indication.
.