3. WP8010 INSTALLATION
Fault
What it means
LOW BATTERY
The battery in a sensor, keyfob or wireless
commander is near the end of its useful life.
MISSING
A device or detector has not reported for
some time to the control panel.
NOT NETWORKED
A device was not installed or not installed
correctly, or, cannot establish communication
with the control panel after installation.
RSSI LOW
The GSM communicator has detected that
GSM network signal is weak
There is no power to the siren
SIREN AC
FAILURE
TAMPER OPEN
The sensor has an open tamper
TROUBLE
The sensor reports trouble
1
SOAK TEST FAIL
Detector alarms when in Soak Test mode

7.2 Dismounting the Control Panel

A. Remove the screw that fastens the front unit to the back unit, see Figure 3.1 WP8010/ 4.1 WP8030B. Remove the
4 screws that fasten the back unit to the mounting surface - see Figure 3.1 (WP8010/ 4.1 WP8030) - and remove
the control panel.

7.3 Replacing the Backup Battery

Replacement and first-time insertion of battery pack is similar, see Figure 3.8 (WP8010 / 4.10 WP8030).
With a fresh battery pack, correct insertion and tightened battery compartment lid, the TROUBLE indicator should
extinguish. However, the "MEMORY" message will now blink in the display (caused by the "tamper" alarm you triggered
when opening the battery compartment lid). Clear it by arming the system and immediately disarming.

7.4 Fuse Replacement

The WP8010has an internal fuse (the WP8030has two internal fuses) that has automatic reset. Therefore, there is no
need to replace the fuse(s).
When over current condition occurs, the fuse cuts off the circuit current. Upon fault current being removed for several
seconds, the fuse is automatically reset and allows current flow through the circuit again.

7.5 Replacing/Relocating Detectors

Whenever maintenance work involves replacement or re-location of detectors, always perform a full diagnostic test
according to section 5.9.
Remember! A "poor" signal is not acceptable.
1
Soak Test is not applicable for UL installations
78
Possible Solution
control panel
 For AC powered devices, check AC power
is available and connected to the device.
Replace the device battery.
 Make sure the device is physically present.
 Check the display for device faults, for
example, low battery.
 Use RF diagnostics to check the current
signal strength and during the last 24
hours.
 Replace the battery.
Replace the device.
 Make sure the device is physically present.
 Use RF diagnostics to check the current
signal strength and during the last 24
hours.
 Open the device cover and replace the
battery or press the tamper switch.
Enroll the device again.
Move the Panel and GSM unit to another
location.
Make sure that the AC power supply is
connected properly
Close sensor tamper
Replace the sensor
If you wish to continue the Soak Test, no
further action should be taken.
If you wish to abort the Soak Test, disable the
Soak Test (see section 5.4.6).