Appendix A: Reporting Codes

The following tables contain Contact ID and Automatic
SIA format reporting codes. For more information on
reporting code formats and notes about individual
reporting codes, (see section 5.6 'Communicator Pro-
gramming' PWS Sect 6).
Contact ID
The first digit (in parentheses) will automatically be sent
by the control panel. The second two digits are pro-
grammed to indicate specific information about the sig-
nal. For example, if zone 1 is an entry/exit point, you
could program the event code as [34]. The central station
would receive the following:
*BURG - ENTRY/EXIT - 1 where the '1' indicates which
zone went into alarm.
Section #
Reporting Code
[320]-[321]
Zone Alarms
[324]-[325]
Zone Restorals
[328]
Duress Alarm
[328]
Opening After Alarm
[328]
Recent Closing
[328]
Zone Expander Supervisory
Alarm/Rest.
[328]
Cross Zone (Police Code)
Alarm
[328]
Burglary Not Verified
[328]
Alarm Cancelled
[329]
[F] Key Alarm/Restoral
[329]
[A] Key Alarm/Restoral
[329]
[P] Key Alarm/Restoral
[329]
Aux Input Alarm/Restoral
[330]-[335]
Zone Tamper/Restoral
[338]
General System Tamper/Rest.
[338]
Keypad Lockout
[339-341]
Closings
[341]
Partial Closing
[341]
Special Closing
[341]
Late to Close
[341]
Exit Fault
[342-344]
Openings
[344]
Auto-arm Cancellation
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
Code Sent When...
Zone goes into alarm
Alarm condition has been restored
Duress code entered at keypad
System disarmed with alarm in memory
Alarm occurs within two minutes of system arming
Panel loses/restores supervisory transmission over the Keybus
from zone expansion modules, or keypads with zone inputs
Two zones go into alarm during any given armed-to-armed
period (incl. 24-hr zones)
This reporting code will be sent after the Burglary Verified Timer
expires after a zone alarm occurs.
This reporting code will be sent if a valid access code is entered
during the Alarm Cancel window
Keypad fire alarm (alarm and restoral reporting codes sent
together)
Keypad auxiliary alarm (alarm and restoral reporting codes sent
together)
Keypad panic alarm (alarm and restoral reporting codes sent
together)
Option#23/24: a panic button wired to PGM 2 is pressed/
access code is entered
Option #04: a 2-wire smoke detector wired to PGM 2 goes
into alarm/alarm is cleared.
Zone is tampered / Tamper condition restored
Enrolled module with tamper inputs has a Tamper alarm/all
module Tampers restored
Maximum number of incorrect access codes has been entered
at a keypad
System armed (user 01-34, 40-42 indicated)
One or more zones bypassed when system armed
Closing (arming) using one of the following methods: quick
arm, auto-arm, keyswitch, function key, maintenance code, DLS
software, wireless key
Whenever the auto-arm pre-alert sounds (if the Late to Close
option is enabled)
When Exit Fault Pre-Alert occurs and Entry Delay expires before
the system is disarmed
System disarmed (user 01-34, 40-42 indicated)
Auto-arm cancelled
44
SIA Format - Level 2 (Hardcoded)
The SIA communication format used in this product fol-
lows the level 2 specifications of the SIA Digital Commu-
nication Standard - October 1997. This format will send
the account code along with its data transmission. The
transmission will look similar to the following at the
receiver:
N Ri01
BA 01
N
=
New Event
Ri01
=
Partition /Area Identifier
BA
=
Burglary Alarm
01
=
Zone 1
NOTE:
A system event will use the Area Identifier Ri00.
Dialer
Direction*
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
T/R
T/R
T/R
O/C
O/C
O/C
O/C
O/C
O/C
O/C
** UU = user number (user01-42); ZZ = zone number (01-32)
Automatic
SIA Auto Rep
Contact ID
Codes**
Codes
See Table 3
See Table 3
(1) 21
HA-00
(4) A6
OR-00
(4) 59
CR-00
(1) 43
UA-00/UH-00
(1) 39
BM-00/BV-00
(3) 78
BG-00
(4) A6
BC-00
(1) 15
FA-00/FH-00
(1) AA
MA-00/MH-00
(1) 2A
PA-00/PH-00
(1) 4A
UA-99/UH-99
(1) 11
FA-99/FH-99
(1) 44
TA-ZZ/TR-ZZ
(1) 45
TA-00/TR-00
(4) 21
JA-00
(4) A2
CL-UU
(4) 7A
CG-ZZ
(4) AA
CL-00
(4) A4
CI-00
(4) 57
EE-00
(4) A2
OP-UU
(4) A5
CE-00

Hide quick links: