Kongsberg EM 712 Maintenance Manual
RIO-P board - dip switch setting
The dip switch setting on the RIO–P board has to be correct.
Transmitter Unit 1 (MASTER): All switches must
A
be set to ON.
The position of the dip switches are shown with
the LED lights on the front of the RIO-P board
when the board is installed and the Transmitter
Unit is powered up.
• MASTER should be lit.
• ID5, ID6 and ID7 should not be lit.
B
Transmitter Unit 2 (SLAVE): Switch 1 and 4 must be set to OFF, switch 2 and 3
must be set to ON.
Note
If there is only one Transmitter Unit in the system, it has to be set to Transmitter Unit
1 (MASTER).
92
451106/B