Kongsberg EM 712 Maintenance Manual
RS-422 serial line using five wires and RJ45 connector
An RS-422 serial line connection is a common way to connect the EM 712 to external
devices. An RS-422 serial line connection can transmit data at rates as high as 10 million
bits per second, and may be sent on cables as long as 1500 meters.
A
Local connection
RJ45 connector
Connection on remote device
B
Unless otherwise specified, this cable must be provided
by the installation shipyard.
Minimum cable requirements
•
: 2 x 3 x 0.2 mm²
Conductors
•
: Overall braided
Screen
•
: 30 V
Voltage
•
Maximum outer diameter
We recommend using a shielded CAT-6A quality or better cable.
186
: Defined by the plugs and/or the cable gland
451106/B