Troubleshooting An Mim; 1Fe/2Fe Module; Introduction; Appearance - H3C SecPath V1000-A Installation Manual

Table of Contents

Advertisement

Installation Manual
H3C SecPath V1000-A Security Gateway
Caution:
If you remove an MIM and do not install a new one right away, you must replace the
blanking filler panel to prevent dust and debris from entering the security gateway
and to provide adequate ventilation.
Do not operate at MIMs near the passageway to avoid accidents to the unit or the
removed MIMs.

8.3 Troubleshooting an MIM

You can read the LEDs on the MIM panel to check that the MIM is correctly installed.
If the MIM on the security gateway does not operate normally, check that:
Correct interface cables are used.
The interfaces are working well by reading the interface LEDs.
The configurations on the MIM are validated by executing the display command.

8.4 1FE/2FE Module

8.4.1 Introduction

1/2-port 10Base-T/100Base-TX Fast Ethernet interface module (1FE/2FE) provides
the communications between the security gateway and LANs.
The 1FE provides one 10/100 Mbps Ethernet interface with the RJ-45 connector while
the 2FE can provide two. Both of them support:
The transmission segment of 100 meter over the category-5 twisted-pair cable.
Operating rates of 100 Mbps and 10 Mbps, with auto-sensing.
Full duplex (commonly used) and half-duplex.

8.4.2 Appearance

I. Appearance of the 1FE module
The following figure shows the 1FE module:
Chapter 8 Multifunctional Interface Modules
8-3

Advertisement

Table of Contents
loading

Table of Contents