3.2 Mounting the Device

You can install your device on a workbench/tabletop or in a rack.

3.2.1 Tabletop/Workbench-Mounting the Device

If a 19-inch standard rack is unavailable, you can place your security gateway on a
clean workbench/tabletop. To prevent any damage, observe the following:
Ensure the table is stable and well earthed.
Reserve the clearance of 10 cm (3.9 in.) around the device for adequate
ventilation.
Do not place any heavy object on the device.

3.2.2 Rack-Mounting the Device

The security gateway can be placed in a 19-inch standard rack. The following table
shows its dimensions:

Table 3-1 Dimensions of the SecPath V1000-A

SecPath V1000-A (W X D X H)
Follow these steps to install the SecPath V1000-A:
Step 1: Check that the rack is stable enough and properly earthed. Attach the
rack-mount brackets to the front or rear of the chassis with screws.
Step 2: Place the device on a shelf in the rack and slide it to a proper position along the
guide rails, reserving a suitable clearance between the device and the guide rails.
Step 3: Fix the brackets to the rack posts with suitable antirust pan-head screws,
making sure that the device is securely fixed.
Model
3-2
Chapter 3 Hardware Installation
Dimensions
436 x 430 x 44 mm (17.2 x 16.9 x 1.7 in),
excluding the rubber feet