Rotax 125 MAX DD2 evo Installation Instructions And Operators Manual page 60

Hide thumbs Also See for 125 MAX DD2 evo:
Table of Contents

Advertisement

NOTE
For draining the oil from the gear case, remove
the magnetic oil drain plug (pos. 1) and sealing
ring (pos. 2). Clean the oil drain plug before in-
stallation. Always use a new sealing ring.
Figure 8.3
Magnetic oil drain
1
plug
NOTE
Tighten magnetic oil drain plug (pos. 1) to 20
Nm (177 lbf.in.).
m WARNING
Non-compliance can result in serious injuries
or death!
Do not run the engine without gear oil. This will
lead to engine failure.
Effectivity: 125 MAX DD2 evo
BRP-Rotax
INSTALLATION MANUAL
2
Sealing ring
7
Page 3
Edition: September 01 2019