4.
SPECIAL FUNCTIONS
4.1.
TEST - Checking the TdC 8000
see page 98
4.2.
BLOCK - Deactivate the Impulse-Channels
You can deactivate each impulse channel (c0 to c9). There are two possibilities to deactivate the
channels.
The TdC 8000 ignores each impulse of a selected channel (channel off)
The TdC 8000 marks each impulse of a selected channel (with ?) . The time does not start or
stop on the display and display board.
Channel 0 (start) and 1 (finish) you can deactivate direct.
4.2.1.
Blocking the Start
-
All start impulses (c0) are not valid and the time of day is marked with a ? as long as you
press <BLOCK> of the start-keyboard (9).
Printer:
Display Board:
RS 232:
As long as you press <ALT> and <BLOCK> of the start-keyboard (9) together, the TdC 8000
will ignore all start impulses (channel 0). The TdC 8000 does not store or output this time.
If you block the start impulse it will not start the clock.
4.2.2.
Blocking the finish
All finish impulses (c1) are not valid and the time of day is marked with a ? as long as you
press <BLOCK> of the finish-keyboard (15). It does not stop the clock and it does not output
a run time.
Printer:
Display Board:
RS 232:
As long as you press <ALT> and <BLOCK> of the finish-keyboard (15) together, the TdC
8000 will ignore all finish impulses (channel 1). The TdC 8000 does not store or output this t
ime.
A stop impulse never stops the time on the display and display board as long as you press
<BLOCK>.
Version: E-01-08-08
TdC 8000 for Equestrian
?0043 ST 10:34:13.384
no output
?0043 C0 10:34:13.384(CR)
?0043 FT 10:34:13.384
no output
?0043 C1 10:34:13.384(CR)
Page 23