LLDP is a one-way protocol without request/response sequences. Information is advertised by stations
implementing the transmit function, and is received and processed by stations implementing the receive
function.
5.11.1.1 LLDP System Settings
The LLDP System Settings allows you to configure the status (enabled or disabled) for the protocol, set the
interval for frame transmission, set the hold time multiplier and the re-initialization delay.
To access this page, click Management > LLDP > LLDP System Settings.
Figure 5.72 Management > LLDP > LLDP System Settings
The following table describes the items in the previous figure.
Item
Enabled
LLDP PDU Disable
Action
Transmission Interval
Holdtime Multiplier
Reinitialization Delay
Transmit Delay
Apply
The ensuing table for LLDP Global Config settings are informational only: LLDP Enabled, LLDP PDU Dis-
able Action, Transmission Interval, Holdtime Multiplier, Reinitialization Delay and Transmit Delay.
90
Description
Click Enabled or Disabled to set the Global Settings state.
Click to select the LLDP PDU handling action when LLDP is globally disabled.
Options include: Filtered, Bridged, or Flooded.
Select the interval at which frames are transmitted. The default is 30 seconds,
and the valid range is 5 to 32768 seconds.
Select the multiplier on the transmit interval to assign to TTL.
Select the delay length before re-initialization.
Select the delay after an LLDP frame is sent.