Wall-Mounting; Figure 4.3 Installing Wall Mount Plates; Figure 4.4 Securing Wall Mounting Screws - Wieland wienet FS8 Series User Manual

Industrial protocol ethrnet switches
Table of Contents

Advertisement

4 Switch Installation

4.3.2 Wall-Mounting

The wall mounting option provides better shock and vibration resistance than the DIN rail vertical mount.
Note
When installing, make sure to allow for enough space to properly install the cabling.
Before the device can be mounted on a wall, you will need to remove the DIN rail plate.
1. Rotate the device to the rear side and locate the DIN mounting plate.
2. Remove the screws securing the DIN mounting plate to the rear panel of the Switch.
3. Remove the DIN mounting plate. Store the DIN mounting plate and provided screws for later
use.
4. Align the wall mounting plates on the rear side. The screw holes on the device and the mount-
ing plates must be aligned, see the following illustration.
5. Secure the wall mount plates with M3 screws, see the following figure. Once the wall mount-
ing plates are secure on the device, you will need to attach the wall screws (x3).

Figure 4.3 Installing Wall Mount Plates

6. Locate the installation site and place the Switch against the wall, making sure it is the final
installation location.
7. Use the wall mount plates as a guide to mark the locations of the screw holes.
8. Drill four holes over the four marked locations on the wall, keeping in mind that the holes must
accommodate wall sinks in addition to the screws.
9. Insert the wall sinks into the walls.
10. Insert the screws into the wall sinks. Leave a 2 mm gap between the wall and the screw head
to allow for wall mount plate insertion.

Figure 4.4 Securing Wall Mounting Screws

22
4.5 mm
3.0 mm
2.0 mm
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
N OTE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents