5 Managing Switch

5.5.3 Port Monitoring

Port Network Monitor is a bandwidth and network monitoring tool for the purpose of capturing network
traffic and measuring of network throughput. The monitoring functionality includes listing of port statistics
as well as port utilization.
5.5.3.1 Port Statistics
To access this page, click Monitoring > Port Monitoring > Port Statistics.
Figure 5.5 Monitoring > Port Monitoring > Port Statistics
The following table describes the items in the previous figure.
Item
Description
Port
Click the drop-down menu to select a port and its captured statistical setting values.
Clear
Click Clear to clear the counter selections.
The ensuing table for IF MIB Counters settings are informational only: ifInOctets, ifInUcastPkts, ifIn-
NUcastPkts, ifInDiscards, ifOutOctets, ifOutUcastPkts, ifOutNUcastPkts, ifOutDiscards, ifInMulticastPkts,
ifInBroadcastPkts, ifOutMulticastPkts and ifOutBroadcastPkts.
The ensuing table for Ether-Like MIB Counters settings are informational only: dot3StatsAlignmentErrors,
dot3StatsFCSErrors, dot3StatsSingleCollisionFrames, dot3StatsMultipleCollisionFrames, dot3StatsDe-
ferredTransmissions, dot3StatsLateCollisions, dot3StatsExcessiveCollisions, dot3StatsFrameTooLongs,
dot3StatsSymbolErrors, dot3ControlInUnknownOpcodes, dot3InPauseFrames and dot3OutPauseFrames.
5.5.3.2 Port Utilization
To access this page, click Monitoring > Port Monitoring > Port Utilization.
Figure 5.6 Monitoring > Port Monitoring > Port Utilization
The following table describes the items in the previous figure.
Item
Description
Refresh period
Click the drop-down menu to select and designate a period (second intervals) to
refresh the information (TX and RX) listings.
IFG
Click the drop-down menu to enable or disable the Interframe Gap (IFG) statistic.
38