5.6

Lamps

Replace before:
BALLAST
3-Phase 7 kW
NOTES: 1) Current range shown includes "over-drive", which is 10% more than the original lamp rating.
2) Optimized brightness requires CDXL lamp.
S
-
TAND
BY LAMP POWER LEVEL FOR
S
-
TAND
BY LAMP POWER LEVEL
M
OTORIZED ADJUSTMENT OF POSITION
5.7

Safety

• CAN/CSA C22.2 No. 60950-1-07
• UL 60950-1
• IEC 60950-1
5.8

EMC Emissions

• FCC CFR47, Part 15, Subpart B, Class A – Unintentional Radiators
• CISPR 22: EN55022: Class A – Radio disturbance characteristics for Information Technology Equipment
(ITE)
5.9

EMC Immunity

CISPR 24/ EN55024: All parts for immunity characteristics for Information Technology Equipment (ITE)

5.10 Operating Environment

Temperature
Humidity (non-condensing)
Altitude
Tilt, any angle
Roadie HD+35K Setup Guide
020-100394-06 Rev. 1 (10-2013)
CXL/CDXL LAMPS (KW)
CXL/CDXL-20 (2.0)
CXL/CDXL-30 (3.0)
CXL/CDXL-45 (4.5)
CXL/CDXL-60 (6.0)
TYPE
4.5/6.0
2.0/3.0
LAMP LIFE (HRS.)
3000
2000
600
600
XENOLITE®
60%
'
OF LAMP
S MAXIMUM CURRENT RATING
75%
'
OF LAMP
S MAXIMUM CURRENT RATING
3-
, 0.25"
AXIS
RANGE FOR EACH
10 to 35°C (50 to 95°F)
20 to 80%
0 – 3000 meters
15 degrees max.