D200/Dx10/Dx20/Dx30 Hpmcs; Table 3-10 D200/Dx10/Dx20/Dx30 Hpmc Codes - HP 9000 Series Service Manual

Enterprise servers
Hide thumbs Also See for 9000 Series:
Table of Contents

Advertisement

D200/Dx10/Dx20/Dx30 HPMCs

The HPMC example in Figure 3-2 shows an example of a CPU error dump.
Figure 3-2 HPMC Error Information Example
--------------------- HPMC Error Log Information ----------------------------
-
Timestamp =
)
HPMC type
= 7000
1. Initial status of HPMC processing; 7000
2. HPMC type detected by the CPU reporting these codes; 7000 (memory error)
To check the chassis code, follow these steps:
1. Reset the system.
2. Stop the autoboot process if it is enabled.
3. From PDC service menu, enter the PIM command. Record or print the PIM report,
specifically timestamps, chassis codes, responder/requester addresses, I/O module
error log, and memory error log.
4. Refer to Table 3-10 for description and action for each HPMC chassis code.

Table 3-10 D200/Dx10/Dx20/Dx30 HPMC Codes

Code
2040
Cache parity error
2043
Data cache HPMC error
2044
Instruction cache HPMC error
2045
Instruction cache HPMC error
503F
Bus HPMC error
70xy
Memory HPMC error
Chapter 3
Sun
Aug
12
18:03:07
Description
GMT
1995
(19:95:08:12:18:03:07
Action
1. Replace Processor/Memory card.
2. Contact the response center.
1. Replace Processor/Memory card.
2. Contact the response center.
1. Replace Processor/Memory card.
2. Contact the response center.
1. Replace Processor/Memory card.
2. Contact the response center.
1. Replace System/Core I/O card.
2. Replace Processor/Memory card.
3. Replace other HSC cards.
4. Contact the response center.
x = SIMM slot number, y = bank. Replace
SIMM in slot x.
Troubleshooting
3- 17