Removal and Replacement Procedures
5. Reconnect hotswap present cable.

Remove and Replace the Hot-Swap Blower (D Class only)

Remove the Blower
1. Remove the upper peripheral bay.
2. Remove the hot-swap bay.
3. Remove any cables from the System/Core I/O Board that obstruct access to the blower.
4. Disconnect the blower cable from the System/Core I/O Board.
5. Remove the blower mounting screw on the left side of the blower.
6. Slide the blower out.
Replace the Blower
1. Slide the blower in and insert the blower fan mounting screws on the left side.
2. Attach the blower cable to the connector on the System/Core I/O Board.
3. Replace the hot-swap bay.
4. Replace the upper peripheral bay.
5. Replace any cables removed from the System/Core I/O Board.