Troubleshooting
Code
7302
SIMM 1 bytes are not equal
7303
SIMM 0 data and SIMM 1 data
7304
SIMM pair not equal size
7305
Multi-bit error occurred during selftest
7306
Address test failed on bank
7307
ECC test failed on bank
7308
Single bit memory error caused HPMC
7401
No memory SIMMs installed
7402
Both EDO and STD memory SIMMs
installed
7403
Address did not map to bank
7404
Invalid memory address
7405
Dual issue processor test failed
7500
No RAM found
7501
Not enough good memory to run Operating
System
7502
Not enough good memory to run Boot
Console Handler
7604
No bits set in test status
7702
Warning, abbreviated memory test
7703
SIMM loading warning
7704
RAM bus warning
7705
not enough good memory to run OS
3-14
Description
Possible Cause
Refer to the memory configuration tables for
the deallocated memory bank.
Refer to the memory configuration tables for
the deallocated memory bank.
Refer to the memory configuration tables for
the deallocated memory bank.
Refer to the PDT for SIMM pair number
Refer to the memory configuration tables for
the deallocated memory bank.
Refer to the memory configuration tables for
the deallocated memory bank.
This is a selftest error, should not occur
during normal operation.
1. Re-seat or install SIMM pairs
2. Replace Processor/Memory card
EDO SIMMs not supported
Replace Processor/Memory card
Replace Processor/Memory card
Replace Processor/Memory card
1. Re-seat or install SIMM pairs
2. Replace Processor/Memory card
Verify memory configuration using PDC ME
command
Verify memory configuration using PDC ME
command.
Replace Processor/Memory card
Fast Boot is Enabled
Verify memory configuration using PDC ME
command. Large SIMM sizes should be
loaded first
Verify memory configuration using PDC ME
command
Verify memory configuration using PDC ME
command
Chapter 3