Image 3-30
A
Connection with local power net.
B
Mono phase power box.
C
Power source cable to Solaris LD tiles.
The power cable for connection between the local net and the power box is not included. A cable with a section of 10 mm
with a 63 ampere switch fuse must be provided to supply the power box. The allowed range of the power voltage is from 190 to 230
volt.
Image 3-31
Mono phase power box (R9851220).
W
ARNING
technical personnel only. Make sure that the local power supply voltage correspond with the required input
voltage of the mono phase power box. Wrong input voltage can cause damage to the power box and the
equipment connected with the power box.

3.6 Solaris LD software

Functionality
The Solaris LD user software has three different levels, namely "Expert", "Operator" and "User" level. In the "Expert" level you can
request for service information etc. Within the "Operator" level you can program and schedule the content which you want to display.
On "User" level you can start and stop scheduled content.
Next to the Solaris LD user software there is the Solaris LD configuration software (XLite toolset) which allows you to configure and
set up the complete Solaris LD display and Solaris D2 digitizer.
For more information about the Solaris LD software, please refer to the user manuals of the Solaris LD soft-
ware.
R5976773 SOLARIS LD DISPLAY 02/12/2004
:
Connecting the power box with the local power net must be performed by authorized and qualified
3. System overview