Zone Response Type Definitions - Honeywell ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for ADEMCO VISTA-120:
Table of Contents

Advertisement

ZONE #
1st
1
01
2
02
3
03
4
04
5
05
6
06
7
07
8
08
9
01
10
02
11
03
12
04
13
05
14
06
15
07
16
08
17
01
18
02
19
03
20
04
21
05
22
06
23
07
24
08
25
01
26
02
27
03
28
04
29
05
30
06
31
07
32
08
33
01
34
02
35
03
36
04
*
The programming of the first digit of each of these zones progresses in the same manner as the protection zones. For example,
zone 601's first digit is 01; zone 602 is 02; zone 608 is 08; etc.

Zone Response Type Definitions

Each zone must be assigned a zone type, which defines
the way in which the system responds to faults in that
zone. There are three keypad-activated zones (panic
keys; see note) for each partition, a polling loop
supervision zone, and four RF supervisory zones, two
for each RF receiver. Zone types are defined below.
Type 00: Zone Not Used
Program with this zone type if the zone is not used.
Type 01: Entry/Exit #1 Burglary
Provides entry delay whenever the zone is faulted and
the system is armed in the AWAY or STAY mode. When
the panel is armed in the INSTANT or MAXIMUM
mode, no entry delay is provided. Exit delay begins
whenever the control is armed, regardless of the arming
mode selected. These delays are programmable.
Assign this zone type to zones that are used for primary
entry to and exit from the facility.
Communication Defaults for Zones
2nd
ZONE #
1st
37
00
05
00
38
06
00
39
07
00
40
08
00
41
01
00
42
02
00
43
03
00
44
04
45
00
05
00
46
06
47
00
07
00
48
08
00
49
01
00
50
02
00
51
03
00
52
04
00
53
05
00
54
06
55
00
07
00
56
08
00
57
01
00
58
02
00
59
03
00
60
04
00
61
05
00
62
06
63
00
07
00
64
08
65
00
01
00
66
02
00
67
03
00
68
04
00
69
05
00
70
06
00
71
07
00
72
08
2nd
ZONE #
1st
73
00
01
00
74
02
00
75
03
00
76
04
00
77
05
00
78
06
00
79
07
00
80
08
81
00
01
00
82
02
83
00
03
00
84
04
00
85
05
00
86
06
00
87
07
00
88
08
00
89
01
00
90
02
91
00
03
00
92
04
00
93
05
00
94
06
00
95
07
00
96
08
00
97
01
00
98
02
99
00
03
00
100
04
101
00
05
00
102
06
00
103
07
00
104
08
00
105
01
00
106
02
00
107
03
00
108
04
Type 02: Entry/Exit #2 Burglary
Provides a secondary entry delay whenever the zone is
faulted and the system is armed in the AWAY and
STAY modes. When the panel is armed in the
INSTANT or MAXIMUM mode, no entry delay is
provided. Secondary exit delay begins whenever the
control is armed, regardless of the arming mode
selected. These delays are programmable.
Assign this zone type to zones that are used for entry
and exit of the facility and require more time than the
primary entry and exit point. Delay times for this zone
type must be greater than those for zone type 01 (e.g., a
garage, loading dock, or basement door).
Type 03: Perimeter Burglary
Provides an instant alarm if the zone is faulted and the
system is armed in the AWAY, STAY, INSTANT, or
MAXIMUM mode.
Assign this zone type to all exterior door and window
zones.
Type 04: Interior, Follower
Section 4 – Programming
2nd
ZONE #
1st
109
00
05
00
110
06
00
111
07
00
112
08
00
113
01
00
114
02
00
115
03
00
116
04
117
00
05
00
118
06
119
00
07
00
120
08
00
121
01
00
122
02
00
123
03
00
124
04
00
125
05
00
126
06
127
00
07
00
128
08
00
601-696*
01
00
800-830*
01
00
988
02
00
990
04
00
992 (DURESS)
06
00
995
01
996
00
02
00
997
07
999
00
03
00
ALARM RST.
00
00
TROUBLE
00
00
TRBLE. RST
00
00
BYPASS
00
00
BYP. RST.
00
00
00
2nd
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
4-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents