Zone Response Type Definitions

General Information
During programming, you must assign a zone type to each zone, which defines the way in which the system
responds to faults in that zone. Zone types are defined below.
Type 00
Zone Not Used
Type 01
Entry/Exit
Burglary #1
01000-017-V0
Type 02
Entry/Exit
Burglary #2
01000-017-V0
Type 03
Perimeter
Burglary
01000-018-V0
Type 04
Interior,
Follower
5890 / 5890PI
01000-019-V1
Type 05
Trouble by Day/
Alarm by Night
Type 06
24-hour
Silent Alarm
Type 07
24-hour
Audible Alarm
Zone type 00 is used to program a zone that is not used.
Zone type 01 is usually assigned to sensors or contacts on primary entry and exit doors.
Zone Characteristics:
Entry delay #1 is programmable from 0-99 seconds (field
Exit delay is independently programmable from 0-99 seconds (field
Exit and entry delays when armed in AWAY or STAY mode.
No entry delay when armed in STAY NO DELAY or AWAY NO DELAY mode.
Exit delay regardless of the arming mode selected.
Zone type 02 is usually assigned to sensors or contacts on which secondary entry and exit
doors that might be further from the keypad (typically used for a garage, loading dock, or
basement door).
Zone Characteristics:
Entry delay #2 is programmable from 0-99 seconds (field
Exit delay is independently programmable from 0-99 seconds (field
Secondary entry delay, if armed in the AWAY or STAY mode.
No entry delay when armed in the STAY NO DELAY or AWAY NO DELAY mode.
Exit delay begins regardless of the arming mode selected.
Zone type 03 is usually assigned to all sensors or contacts on exterior doors and windows.
Zone Characteristics:
Instant alarm, when armed in AWAY, STAY, STAY NO DELAY, or AWAY NO DELAY
mode.
Zone type 04 is usually assigned to a zone covering an entry area (i.e.: foyer, lobby, or
hallway) that one must pass upon entry (after faulting the entry/exit zone) to reach the
keypad. It provides an instant alarm if the entry/exit zone is not violated first, and protects
an area in the event an intruder has hidden on the premises before the system is armed, or
gains access to the premises through an unprotected area.
Zone Characteristics:
Delayed alarm (using the programmed entry/exit time) if entry/exit (types 01 or 02) or
interior-with-delay (type 10) zone is faulted first.
Instant alarm in all other situations.
Active when armed in AWAY or AWAY NO DELAY mode.
Bypassed automatically when armed in STAY or STAY NO DELAY mode.
Zone type 05 is usually assigned to a zone that contains foil-protected doors or windows or
covers a sensitive area (i.e.: stock room, drug supply room, etc.) It can also be used on a
sensor or contact in an area where immediate notification of an entry is desired.
Zone Characteristics:
Instant alarm, when armed in AWAY, STAY, STAY NO DELAY, or AWAY NO DELAY
(night) mode.
Provides a latched trouble sounding from the keypad and, if desired, a central station
report during the disarmed state (day).
Zone type 06 is usually assigned to a zone containing an Emergency button (silent
emergency).
Zone Characteristics:
Sends a report to the central station but provides no keypad display or sounding.
Zone type 07 is usually assigned to a zone containing an Emergency button (audible
emergency).
Zone Characteristics:
• Sends a report to the central station, and provides alarm sounds externally and at the
keypad.
- 18 -
35).
34).
36).
34).