VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
∗ ∗ ∗ ∗ 34

Secondary Phone Number

Enter 0-9; #11 for ∗, #12 for #, #13 for a 2-
second pause.
∗ ∗ ∗ ∗ 35

Download Phone Number

Enter 0-9; #11 for ∗, #12 for #, #13 for a 2-
second pause.
∗ ∗ ∗ ∗ 36

Download ID Number

Make entries as 2-digit numbers as follows:
00=0 01=1
06=6 07=7
12=C 13=D 14=E 15=F
∗ ∗ ∗ ∗ 37

Download Command Enables

0 = disable
1 = enable
∗ ∗ ∗ ∗ 38

Prevent Zone XXX Bypass

(partition-specific)
Enter a zone number (001-250).
Enter 000 if all zones can be bypassed.
∗ ∗ ∗ ∗ 39
Enable Open/Close Report for
Installer Code (partition-specific)
0 = disable
1 = enable
∗ ∗ ∗ ∗ 40
Enable Open/Close report for
Keyswitch
0 = disable
1 = enable
∗ ∗ ∗ ∗ 41
Normally Closed or EOLR (Zones
2-8)
0 = EOLR used
1 = normally closed
∗ ∗ ∗ ∗ 42

Dial Tone Pause

Enter the wait time for dial tone detection:
0 = 5 seconds; 1 = 11 seconds; 2 = 30
seconds.
∗ ∗ ∗ ∗ 44

Ring Detection Count

Enter 00 to disable ring detection.
Enter 01-14 for ring counts of 1-14.
Enter 15 to select Answering Machine Defeat
Mode
5-4
02=2
03=3
04=4
05=5
08=8
09=9
10=A 11=B
EXPLANATION
Enter the secondary phone number, up to 17 digits. The secondary phone
number is used if communication on the primary number is unsuccessful, or if
split/dual reporting is desired. Do not fill unused spaces.
NOTE: If this field is programmed, a secondary subscriber account number
(field *90) must also be programmed.
Enter the downloading phone number, up to 17 digits. Do not fill unused
spaces.
NOTE: This field is applicable only if downloading is utilized.
Enter eight digits.
NOTE: This field is applicable only if downloading is utilized.
Enabling a function means that you are able to perform that function via the
ADEMCO Compass Downloading software.
Functions are as follows: Dialer Shutdown; System Shutdown; Not Used;
Remote Bypass; Remote Disarm; Remote Arm; Upload Program; Download
Program.
For UL installations, all entries must be 0.
Enter three digits for zone that cannot be bypassed by the user.
NOTES:
The actions manual bypass, group bypass, auto-stay, and STAY/INSTANT
arming modes cannot bypass any zone programmed in this field.
The system will not arm if the zone is programmed with the vent zone or force
arm fault attributes.
Force Arming is not a ULC Listed feature and
U LC
must be disabled for ULC installations.
If enabled, whenever the Installer Code is used to arm or disarm the partition,
an open/close report is sent to the central station.
If enabled, whenever the keyswitch is used to arm or disarm the partition, an
open/close report is sent to the central station.
If 0, end-of-line resistors must be used on zones 2-8.
If 1 end-of-line resistors cannot be used and only normally closed devices
must be used.
Must be 0 for UL installations.
Enter the time the system waits for dial tone before dialing.
Must be 0 for UL installations.
Only applicable if station-initiated downloading will be used.
NOTES:
In the Answering Machine Mode, the caller should let the phone ring once,
then hang up, and call again within 30 seconds. The system, upon hearing
one ring followed by nothing, does not answer the first call, but readies itself to
pick up on the first ring of the next incoming call that is received within 30
seconds (i.e., the downloader calling again).
Must be 00 for UL installations.