Remove and Replace System Components
1
Figure 19
1
2
3
4
Removing a power supply
98
EMC Connectrix B Series ED-48000B Hardware Reference Manual
Figure 19
identifies the locations of the AC power connectors and AC
power switches on the ED-48000B chassis. In order for the power
supply units to function correctly, the AC power connector cables
must be plugged in to the AC power connectors and the AC power
switches must be turned on.
200-240 V A C 12A 50-60 Hz 200-240 V A C 12A 50-60 Hz
2
AC power connectors and ac power switches on the ED-48000B
chassis
AC Power Switch (controls the power for power supplies 1 and 3)
AC Power Connector (connects to the AC power cables for power supplies 1 and 3)
AC Power Connector (controls the power for power supplies 2 and 4)
AC Power Switch (connects to the AC power cables for power supplies 2 and 4)
To remove a power supply:
1. If the ED-48000B is not operating during the replacement
procedure, skip to step 2.
If the ED-48000B is going to continue operating during the
replacement procedure, check the power LEDs to verify that the
minimum number of power supply units required is still
functioning: A fully populated ED-48000B requires a minimum of
one power supply unit in any slot at all times to ensure power to
the director. For maximum availability of the ED-48000B director,
you should have a minimum of one power supply unit in slot 1 or
3, and one in slot 2 or 4.
2. Push the locking tab toward the power supply unit and pull the
handle out and down.