2005/03/07-15:05:56, [SULB-1002], 924,, INFO,
completed successfully.
9. Type firmwareDownloadStatus to verify that the firmware
downloaded successfully.
10. Type haEnable to reenable HA on the active CP blade.
11. Type
.
reboot
12. Verify that the reboot is complete and the CP blades have
achieved failover redundancy:
a. Wait until the status LEDs on both CP blades are not lit.
b. Type haShow and verify that the command output includes
"HA Enabled Heartbeat Up". If not, wait a minute and
re-enter the command, until you have verified that
redundancy is achieved.
13. Type firmwareShow to verify that the firmware version has been
updated.
14. Pack the old CP blade in the packaging provided with the new CP
blade, and contact your EMC service representative to determine
the return procedure.
Remove and Replace System Components
48000
, Firmwaredownload command has
Replacing a CP blade