EMC Connectrix B Series Hardware Reference Manual page 59

Hide thumbs Also See for Connectrix B Series:
Table of Contents

Advertisement

Table 3
LED Purpose
Color
Power LED
Steady green
No light (LED is off)
Status LED
No light (LED is off)
Steady amber
Slow-flashing amber (on 2
seconds; then off 2 seconds)
Fast-flashing amber (on 1/2
second; then off 1/2 second)
Port Speed LED
No light (LED is off)
Steady green
Steady amber
Table 3
describes the port blade LED patterns and the recommended
actions for those patterns for the ED-48000B.
Port blade LED descriptions
Status
Port blade has valid power.
Port blade does not have
incoming power.
Port blade is either healthy or
does not have power.
Port blade is faulty.
Port blade is not seated
correctly or is faulty.
Environmental range
exceeded.
Port is either set to 1 Gb/sec
mode, or it does not have
incoming power.
Port is set to 2 Gbit/sec
mode.
Port is set to 4 Gbit/sec
mode.
Monitor System Components
Recommended Action
No action required.
Ensure blade is firmly seated and has
power.
Verify that the power LED is on.
Ensure blade is firmly seated and check
status with slotShow command. If LED
remains amber, consult your EMC service
representative.
Pull blade out and reseat it. If LED
continues to flash, replace blade.
Check for out-of-bounds environmental
condition and correct it.
Verify that the power LED is on. Type the
portCfgSpeed command to change mode.
No action required.
No action required.
Port blades
59