CHASSIS/WWN
Unit: 1
2)
Header Version:
Power Consume Factor:
Factory Part Num:
Factory Serial Num:
Manufacture:
Update:
Time Alive:
Time Awake:
<output truncated>
swDir:admin>
7. Create a SAN "profile" by entering and recording the information
provided by the following commands:
• nsShow
• nsAllShow
• switchShow
• fabricShow
Copy the command output into a text file named "SANbefor.txt".
This information can be used after the ED-48000B is restored to
the fabric, to verify that no unintentional changes have occurred
to the fabric.
swDir:admin> nsshow
Type Pid COS PortName NodeName TTL
<output truncated>
swDir:admin> nsallshow
12 Nx_Ports in the Fabric
<output truncated>
swDir:admin> switchshow
switchName: switch
<output truncated>
swDir:admin> fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
<output truncated>
swDir:admin>
187 days
3 days
(in same assembly as WWN Unit:
2
-3
60-0001501-07
FT02X805BE2
Day: 26
Month:
Day: 14
Month:
207 days
3 days
Record critical switch and SAN information
Chassis Replacement