Note: Enter all remaining commands from the serial console for the
active CP blade, unless otherwise indicated. For more information about
commands, refer to the Fabric OS Command Reference Manual.
3. If the healthy CP blade is performing as the active CP blade,
continue with step 5 on page 90. If the faulty CP blade is
performing as the active CP blade, fail over the blades as
described here:
a. Log in to the faulty CP blade as admin, using either a Telnet or
b. Type
c. Wait until the status LED on the healthy CP blade is no longer
d. Type
Fabric OS (cp1)
cp1 login: admin
Password:
swDir:admin> hashow
Local CP (Slot 6, CP1): Active
Remote CP (Slot 5, CP0): Standby, Healthy
HA enabled, Heartbeat Up, HA State synchronized
swDir:admin> hafailover
Local CP (Slot 6, CP1): Active
Remote CP (Slot 5, CP0): Standby, Healthy
HA enabled, Heartbeat Up, HA State synchronized
Warning: This command is being run on a redundant control
processor(CP) system. If the above status does not indicate
a serial console connection.
If you connect successfully to the faulty CP continue to step b.
If you cannot connect to the faulty CP, remove the faulty CP
blade for repair as follows:
– Turn the CP blade off and notify the ED-48000B of a
hot-swap request by sliding the slider switch in the top
ejector down to the off position (see
– Wait until the active CP LED on the healthy CP blade is lit.
You can remove the CP for repair.
. The healthy CP blade becomes the active
haFailover
CP blade.
lit (indicating the failover is complete).
from the healthy CP blade (the new active CP
haShow
blade) to verify the failover.
Following is an example of failing over a CP blade in an
ED-48000B: