8. Log in to the switch from the remote client as admin. The default
password is "password".
Note: If the Off Hook indicator illuminates on the standby CP blade
modem, recheck the modem cable connection to the active CP blade.
9. Log out of the modem session.
10. Remove the telco connector from the active CP blade modem,
leaving the telco line from the standby CP blade connected to the
"Y" connector (see
Note: The modem session is automatically disconnected if the modem
cable is detached while a session is active.
11. Dial in to the telephone number assigned to the ED-48000B, as
described in
"Setting up a remote modem system" on page
12. Observe the modem lamps: the Ring indicator should flash only
on the modem connected to the standby CP blade.
13. Verify that after seven rings, the Off Hook indicator on the
standby CP blade modem is illuminated. A login prompt is
presented to the remote client, and a message confirms that the
standby CP blade is being logged in to. You can log in or
disconnect the session, as desired.
14. Reconnect the telco connector to the active CP blade modem.
The ED-48000B modems are ready for use.
Figure 23 on page
160).
Verifying the modem connection
Setting Up and Installing Modems
162.
165