Initial Configuration Parameters
46
EMC Connectrix B Series ED-48000B Hardware Reference Manual
Enter the requested information at the prompts. Unlike the
ED-12000B or ED-24000B, the only valid configuration for the
ED-48000B is as a single domain (single logical switch), so you
only need to specify the -sw 0 IP address. There is no -sw 1 in the
ED-48000B.
3. Set up the CP0 IP address by entering the ipaddrset -cp 0
command:
swDir:admin> ipAddrSet -cp 0
Enter the requested information at the prompts.
4. Set up the CP1 IP address by entering the ipaddrset -cp 1
command:
swDir:admin> ipAddrSet -cp 1
Enter the requested information at the prompts.
Following is a sample IP configuration:
swDir:admin> ipaddrset -sw 0
Ethernet IP Address [0.0.0.0]: 123.123.123.120
Ethernet Subnetmask [0.0.0.0]: 123.123.123.123
Fibre Channel IP Address [0.0.0.0]:
Fibre Channel Subnetmask [0.0.0.0]:
Issuing gratuitous ARP...Done.
Committing configuration...Done.
swDir:admin> ipaddrset -cp 0
Host Name [cp0]:
Ethernet IP Address [10.77.77.75]: 123.123.123.121
Ethernet Subnetmask [0.0.0.0]: 123.123.123.123
Gateway IP Address [0.0.0.0]: 123.123.123.124
IP address is being changed...Done.
Committing configuration...Done.
swDir:admin> ipaddrset -cp 1
Host Name [cp1]:
Ethernet IP Address [10.77.77.74]: 123.123.123.122
Ethernet Subnetmask [0.0.0.0]: 123.123.123.123
Gateway IP Address [0.0.0.0]: 123.123.123.124
IP address of remote CP is being changed...Done.
Committing configuration...Done.
swDir:admin> reboot
5. Reboot the ED-48000B director by typing
at the prompt.
reboot