Setup Relating to Operations From the Control Panel
(OPERATION Menu)
13-66
Chapter 13 Setup
4
Press F2 (TYPE) to select the type of link.
OFF: No operation.
BUS: Link two buses.
GPI: Link a button on the control panel to a GPI output port.
• When you select "BUS," proceed to step 5.
• If you select "GPI," continue with the procedure in the next section,
"Linking a button to a GPI output port."
5
Press F9 (MASTER/LINK) to set F9 to "MASTER."
The indication for F10 changes to "MASTER SELECT."
6
Press F10 (MASTER SELECT) or turn knob 3 to align the cursor with
the bus you wish to select as the master, then press F8 (SELECT).
This selects the bus with which the cursor is aligned as the master bus.
7
Press F9 (MASTER/LINK) to set F9 to "LINK."
The indication for F10 changes to "LINK SELECT."
8
Press F10 (LINK SELECT) or turn knob 3 to align the cursor with the
bus you wish to link to the master bus selected in step 6, then press F8
(SELECT).
This confirms the selection of the bus with which the cursor is aligned.
9
Press F5 (AUTOSEL) to select one of the five "auto select tables" in
which are set the correspondences of cross-point buttons between the two
buses.
To change the auto select table setting, proceed to step 10.
10
Press F3 (AUTOSEL SETUP).
The AUTO SEL SETUP menu appears.
11
Press F2 (AUTOSEL SELECT), to align the cursor with the auto select
table you wish to select.