Short start–up, standard settings
The setting elements for the user–friendly interface are located on the parame-
ter board, for the standard interface, on the control (refer to Section 9 Appen-
dix). The tachometer adaptation, current normalization and current controller
gain parameters should be set for a standard start–up.
Tachometer adaptation for motors with tachometer
voltages
16.5 V at rated speed
Only for 1FT503 – AF71 and 1FT504 – AF71 motors
User–friendly– and
All three contacts, switch S1 (S4 for the 2nd axis standard interface) = ON
standard interface
Further, an adjustment can be made using discrete resistors.
Current controller settings
The settings for the current limit and current controller gain Kp(I) can be taken
from the adaptation tables, Table 1-3 up to Table 1-9. If the required feed mo-
dule/motor combination cannot be found, the values can be determined using
the associated formulas.
User–friendly inter-
Parameter board, switch S2
face
Standard interface
Control board, switch S2 (S5 for 2nd axis)
Note
The following setting values are valid for both control versions, as long as, in
individual cases, specific reference is not made to differences.
Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and Start–Up Guide/IAA/–04.97 Edition
1 Short start–up, standard settings