Setting elements with user–friendly interface
Setting elements on the parameter board; terminal = H
with terminal 9, terminal = L
Function
Ready/fault
Relay terminal 672/673/674
Speed/current controlled
(permanently selected via switch)
Speed/current controlled
(selected via terminal)
Supplementary setpoint 1 via terminal
22 = H
Supplementary setpoint 2 via terminal
23 = H
Current–controlled operation with/
without I component
Controller– and pulse inhibit via
terminal 65
Master-/slave operation: Master opera-
tion
Slave operation
Timer, speed controller at its endstop
Monitoring, n controller at n stop
Direction of rotation reversal
(direction of rotation for a positive set-
point at terminal 56/14)
Speed controller smoothing
Speed setpoint smoothing
Speed actual value smoothing
Current setpoint smoothing
2)
Speed setpoint adaptation
(only terminal 56/14)
Current setpoint adaptation
Travel to endstop
(set using R12)
1) As supplied: R14 = open
(
N
N
set
rated
2) R=
– 0.5
10V
N
max
Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and Start–Up Guide/IAA/–04.97 Edition
3.2 Setting elements with user–friendly interface
open.
Component(s)
R33 = 0 Ω (as supplied)
R33 = open
S2: 10 = OFF (as supplied)
S2: 10 = ON
R14 = 0 Ω
1)
; terminal 22 = L
R14 = 0 Ω; terminal 22 = H
R16 (as supplied = open)
R17 (as supplied = open)
R18 (as supplied = open)
R21 (as supplied = open)
R19 (as supplied = open)
R22 (as supplied = open)
R1 = 0 Ω (as supplied)
R1 = open
R13 = open (as supplied)
R13 = 0 Ω
R42 + R44 = 0 Ω, S2: 10 = OFF
R44 = 0 Ω, R1 + R42 = open,
S2: 10 = ON
R54 = 360 kΩ (as supplied)
R54 as selected
R32 = 0 Ω (as supplied)
R32 = open
S2: 1 = ON (as supplied)
S2: 1 = OFF
C3 (as supplied = open)
C4 (as supplied = open)
C5 (as supplied = open)
C6 (as supplied = open)
R5 = 20 kΩ (as supplied)
R42 (as supplied = 0 Ω)
R12 according to Fig. 3–3
Condition: Terminal 96 connected to
terminal 44
)
40 k
Feed modules (VS)
jumpered
Effect
Ready signal
fault signal
Closed–loop speed control
closed–loop current control
Closed–loop speed control
closed–loop current control
2)
Voltage divider at 10 V
Voltage divider at –10 V
Voltage divider at the ref. point
2)
Voltage divider at 10 V
Voltage divider at –10 V
Voltage divider at the ref. point
I component inhibited P
I component active PI
Delayed
Instantaneous
Master operation, terminal 258 = out-
put
Slave operation, terminal 258 = input
t = 230 ms
t [ms]
R54 [kΩ] =
0.56
Monitoring active
Monitoring inactive
Motor ccw, drive shaft end
Motor cw, drive shaft end
τ = C3 68 kΩ
τ = C4 10 kΩ
τ = C5 5 kΩ
τ = C6 1 kΩ
|100% n
|=11 ... 5V
ACTN
2)
I
10 V
set
Limiting according to Fig. 3–3
Speed controller monitoring inactive
– 47