Setting Elements With User-Friendly Interface - Siemens SIMODRIVE 611A Installation And Planning Manual

Transistor pwm inverters and motors for ac feed drives
Table of Contents

Advertisement

04.97
07.94
Setting elements with user–friendly interface
Setting elements on the parameter board; terminal = H
with terminal 9, terminal = L
Function
Ready/fault
Relay terminal 672/673/674
Speed/current controlled
(permanently selected via switch)
Speed/current controlled
(selected via terminal)
Supplementary setpoint 1 via terminal
22 = H
Supplementary setpoint 2 via terminal
23 = H
Current–controlled operation with/
without I component
Controller– and pulse inhibit via
terminal 65
Master-/slave operation: Master opera-
tion
Slave operation
Timer, speed controller at its endstop
Monitoring, n controller at n stop
Direction of rotation reversal
(direction of rotation for a positive set-
point at terminal 56/14)
Speed controller smoothing
Speed setpoint smoothing
Speed actual value smoothing
Current setpoint smoothing
2)
Speed setpoint adaptation
(only terminal 56/14)
Current setpoint adaptation
Travel to endstop
(set using R12)
1) As supplied: R14 = open
(
N
N
set
rated
2) R=
– 0.5
10V
N
max
Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and Start–Up Guide/IAA/–04.97 Edition
3.2 Setting elements with user–friendly interface
open.
Component(s)
R33 = 0 Ω (as supplied)
R33 = open
S2: 10 = OFF (as supplied)
S2: 10 = ON
R14 = 0 Ω
1)
; terminal 22 = L
R14 = 0 Ω; terminal 22 = H
R16 (as supplied = open)
R17 (as supplied = open)
R18 (as supplied = open)
R21 (as supplied = open)
R19 (as supplied = open)
R22 (as supplied = open)
R1 = 0 Ω (as supplied)
R1 = open
R13 = open (as supplied)
R13 = 0 Ω
R42 + R44 = 0 Ω, S2: 10 = OFF
R44 = 0 Ω, R1 + R42 = open,
S2: 10 = ON
R54 = 360 kΩ (as supplied)
R54 as selected
R32 = 0 Ω (as supplied)
R32 = open
S2: 1 = ON (as supplied)
S2: 1 = OFF
C3 (as supplied = open)
C4 (as supplied = open)
C5 (as supplied = open)
C6 (as supplied = open)
R5 = 20 kΩ (as supplied)
R42 (as supplied = 0 Ω)
R12 according to Fig. 3–3
Condition: Terminal 96 connected to
terminal 44
)
40 k
Feed modules (VS)
jumpered
Effect
Ready signal
fault signal
Closed–loop speed control
closed–loop current control
Closed–loop speed control
closed–loop current control
2)
Voltage divider at 10 V
Voltage divider at –10 V
Voltage divider at the ref. point
2)
Voltage divider at 10 V
Voltage divider at –10 V
Voltage divider at the ref. point
I component inhibited P
I component active PI
Delayed
Instantaneous
Master operation, terminal 258 = out-
put
Slave operation, terminal 258 = input
t = 230 ms
t [ms]
R54 [kΩ] =
0.56
Monitoring active
Monitoring inactive
Motor ccw, drive shaft end
Motor cw, drive shaft end
τ = C3 68 kΩ
τ = C4 10 kΩ
τ = C5 5 kΩ
τ = C6 1 kΩ
|100% n
|=11 ... 5V
ACTN
2)
I
10 V
set
Limiting according to Fig. 3–3
Speed controller monitoring inactive
– 47
1-107
VS