Interface Overview - Siemens SIMODRIVE 611A Installation And Planning Manual

Transistor pwm inverters and motors for ac feed drives
Table of Contents

Advertisement

02.98

Interface overview

Note
When using non–PELV circuits, connected at terminals AS1, AS2, termi-
nals 111, 113 and 213, the connector coding must prevent the connector being
incorrectly inserted.
Refer to Catalog NC60.1 for the Order Nos. of the coding plugs.
Only PELV circuits may be connected to terminal 19.
Interface overview NE modules
The interface description is valid for all NE modules with the exception of the UE
module 5/10 kW – this interface has its own description
(refer to p. 1-42).
Table 3-8
Term.
Des.
Function
No.
U1
Supply connection
V1
W1
L1
Contactor supply
L2
PE
Protective conductor
P600
DC link
M600
DC link
Grounding bar
P600
DC link
M600
DC link
1R,
TR1,
External resistance
9)
2R,
TR2
connection
3R
X131
Electronics M
1) I = input; O = output; NC = NC contact; NO = NO contact; (for signal, NO = high; NC = low)
2) Terminal 19 is the reference ground (connected inside the module with 10 k
X131/terminal 15)
It is not permissible that terminal 15 is connected to PE or terminal 19, further, no external voltage sources
may be connected to terminal 15. Terminal 19 may be connected to X131.
3) I/R = Infeed/regenerative feedback module; UE = Uncontrolled infeed; MM = Monitoring module;
PW = Pulse resistor module
4) The 1st number is valid for cable lugs. The 2nd number is valid for finely–stranded conductors
without connector sleeve.
5) The grounding bar is used to ground the DC link M rail through 100 kΩ
(should preferably be inserted).
6) RESET = Resets the error memory, edge triggered for the complete drive group
(Terminal "R"
Terminal 15 = RESET)
7) Terminals 111-213, positively–driven NC contact (for I/R 16 kW and UE 10 kW, only from Order No.:
6SN114 –1
01–0
)
Terminals 111–113 NO contacts, not positively driven
8) Maximum current load of terminal 9 with respect to 19: 0.5 A.
9) Only for UE 28 kW
Siemens AG 1998 All Rights reserved
SIMODRIVE 611 (PJ)
Type
Typ. voltage/limit values
1)
E
3–ph. 400 V AC
I
2–ph. 400 V AC, directly from
I
the supply
L1, L2, L3, refer to Sect. 9.2
I
0 V
I/O
+300 V
I/O
–300 V
5)
I/O
–300 V
I
+300 V
I
–300 V
I/O
V300
I/O
0 V
6SN1197–0AA00 02.98 Edition
3.3.1 Interface overview NE modules
Max. cross–
Terminals avai-
section
Refer to
Section 4.2
I/R, UE
2
2 4)
16mm
/10mm
I/R 80/104 kW,
16mm2
2 4)
/10mm
Bolt
I/R, UE, monito-
Busbar
ring module, pul-
Busbar
sed resistor
Busbar
I/R, UE
2
2 4)
16mm
/10mm
Monitoring
2
2 4)
16mm
/10mm
module
2
2 4)
6mm
/4mm
Pulsed resistor;
UE 28 kW
2
2
16mm
/10mm
4)
I/R, UE. monito-
ring module
to the general reference ground
3)
lable in
120/156 kW
1-35