Siemens SIMODRIVE 611A Installation And Planning Manual page 43

Transistor pwm inverters and motors for ac feed drives
Table of Contents

Advertisement

02.98
Table 3-9
T.–
Des.
No.
111
X161
Signaling contact
213
X161
Line contactor
2)4)
9
X141B
FR+
112
X141B
Setting–up no–/standard mode
48
X141B
Contactor control
NS1
X141B
Coil contact for line–,
NS2
X141B
pre–charging contactor
15
X141B
M
1)
I = input; O = output; NC = NC contact; NO = NO contact
2)
Terminal 19 is the reference terminal (this is connected in the module with 10 k to general reference ground
X131)
It is not permissible to connect terminal 15 with PE or with terminal 19, further, no external voltage sources
may be connected to terminal X131.
3)
The grounding bar is used to ground the DC link M rail through 100 kΩ (should be preferably inserted).
4)
Max. current load of terminal 9 – terminal 19
Caution: Terminals 7, 45, 44 and 10 are not available for UE 5/10 kW.
Siemens AG 1998 All Rights reserved
SIMODRIVE 611 (PJ)
3.3.2 Interface overview UE module 5/10 kW
Type
Function
1)
I
1–ph. 250 V AC/50 V DC/2 A
NC
17 V DC/3 mA min
O
+24 V
I
+13 V...30 V/R
I
+13 V...30 V/R
O
+24 V
I
0/+24 V
O
0 V
1 A
6SN1197–0AA00 02.98 Edition
Typ. voltage/limit values
= 1.5 kΩ
E
= 1.5 kΩ
E
Max. cross–
section
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
1-43
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents