Profibus Input Parameters (In-Pzd X) - BONFIGLIOLI Vectron Agile Series Communications Manual

Profibus
Table of Contents

Advertisement

Handling of the Objects
16.3.3

Profibus Input Parameters (IN-PZD x)

The table below lists the available input parameters of the PZD In objects. The content of the sources
depends on the application. For the different data types the equivalent input parameters must be
connected to the inverter sources.
Note:
− The availability of In parameters depends on the number of configured PZD objects.
− Every configured PZD object consists of either two Boolean, two word or one long
input parameter.
− One PZD In object can be used for one data type only (depending on the application
requirements).
− The first configured PZD object (mandatory) represents the PZD1/2 with fixed
contents and functions.
1300 ... 1339 IN-PZD x
No, of
configured
PZD Objects
2
In-PZD 3 Boolean
In-PZD 4 Boolean
3
In-PZD 5 Boolean
In-PZD 6 Boolean
4
In-PZD 7 Boolean
In-PZD 8 Boolean
5
In-PZD 9 Boolean
In-PZD 10 Boolean
6
In-PZD 11 Boolean
In-PZD 12 Boolean
7
In-PZD 13 Boolean
In-PZD 14 Boolean
8
In-PZD 15 Boolean
In-PZD 16 Boolean
9
In-PZD 17 Boolean
In-PZD 18 Boolean
The default setting for all input parameters (except parameters 1302/1303/1307/1308) is FALSE or
zero.
The default setting for input parameters 1302/1303/1307/1308 is compatible to device series ACT with
CM-PDP module:
In-PZD 3 Word
1302 = 770 PDP absolute current
In-PZD 4 Word
1303 = 771 PDP active current
In-PZD 5 Word
1307 = 772 warning status
In-PZD 6 Word
1308 = 773 error status
− If one object is set to a specific source no., be sure that the corresponding objects for
Note:
the same location are set to their default values. This method is the same as used
with Systembus transmit objects.
− Boolean inputs are representatives for boolean objects.
− Word inputs are representatives for current or torque objects.
− Long inputs are representatives for frequency or position objects.
06/2010
Boolean Parameter
Name
Parameter
No.
1300
1301
1305
1306
1310
1311
1315
1316
1320
1321
1325
1326
1330
1331
1335
1336
Profibus DP V1 Agile
Word Parameter
Name
Parameter
No.
In-PZD 3 Word
1302
In-PZD 4 Word
1303
In-PZD 5 Word
1307
In-PZD 6 Word
1308
In-PZD 7 Word
1312
In-PZD 8 Word
1313
In-PZD 9 Word
1317
In-PZD 10 Word
1318
In-PZD 11 Word
1322
In-PZD 12 Word
1323
In-PZD 13 Word
1327
In-PZD 14 Word
1328
In-PZD 15 Word
1332
In-PZD 16 Word
1333
In-PZD 17 Word
1337
In-PZD 18 Word
1338
Long Parameter
Name
Parameter
No.
In-PZD 3/4 Long
1304
In-PZD 5/6 Long
1309
In-PZD 7/8 Long
1314
In-PZD 9/10 Long
1319
In-PZD 11/12 Long
1324
In-PZD 13/14 Long
1329
In-PZD 15/16 Long
1334
In-PZD 17/18 Long
1339
37