BONFIGLIOLI Vectron Agile Series Communications Manual page 47

Profibus
Table of Contents

Advertisement

Handling of the Objects
The Status Word displays the current operation state.
State
Switch On disabled
Ready to Switch On
Switched On
Operation enabled
Quick Stop active
Fault Reaction active
Fault
"X" means any value.
Bit 7 "Warning" can be set at any time. It indicates a device-internal warning message.
The evaluation of the warning reason is carried out by reading out the warning status with Parameter
Warnings
270.
Bit 9 "Remote" is set if the operation mode "control via state machine" (
been set and the hardware release is available.
Logic linking of the digital control signals:
The frequency inverter can only be controlled if the logic linking is true. The logic inputs for Start
clockwise and Start anticlockwise can be connected directly to "ON" or "OFF" (Parameter
clockwise
68 and
Bit 10 "Target reached" is set whenever the specified reference value has been reached.
In the special case of power failure regulation, the bit is also set if the power failure regulation has
reached the frequency 0 Hz (see operating instructions).
For "Target reached" there is a hysteresis (tolerance range), which can be set via parameter
Value Reached: Hysteresis
Bit 11 "Internal limit active" indicates that an internal limit is active. This can, for example, be the
present current limit, the torque limit or the over-voltage limit. All of these limit functions lead to the
reference value being quit or not reached.
Bit 15 "Warning 2" indicates a warning which leads to a fault switch-off of the frequency inverter
within a short period of time. This bit is set if there is a warning for motor temperature, heat
sink/inside temperature, Ixt monitoring or mains phase failure.
06/2010
Status Word
Bit 6
Bit 5
Switch On
Quick
disabled
Stop
1
X
0
1
0
1
0
1
0
0
0
X
0
X
(STOA AND STOB) AND (Start clockwise OR Start anticlockwise)
Start-anticlockwise
69).
549 (see operating instructions).
Profibus DP V1 Agile
Bit 3
Bit 2
Bit 1
Fault
Operation
Switched
enabled
On
0
0
0
0
0
0
0
1
0
1
1
1
1
0
Bit 0
Ready to
Switch On
0
0
0
1
1
1
1
1
1
1
1
1
0
0
Local/Remote
412 = 1) has
Reference
Start-
47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents