Basic Parameters; Menu Branch Para - BONFIGLIOLI Active ACT 201-05 Brief Manual

230 v / 400 v 0.55 kw ... 30.0 kw
Table of Contents

Advertisement

8
8.1
The parameters displayed in the PARA menu branch are partly set via the guided
commissioning. The parameters documented in the brief instructions are
complemented by the information given in the operating instructions.
Control Level
The parameters of the higher control levels 2 or 3 are described in the operating
instructions and should be set up by expert operators only.
Setting:
Configuration
the assignment of the software modules is selected by the configuration. The
selection is made during the guided commissioning.
Setting:
Program(ming)
message is acknowledged (alternative to signal at digital input S1IND).
Setting:
Motor type
entered rated values and the guided commissioning are carried out on the basis of
the parameterized motor type.
Setting:
Rated Voltage
asynchronous motor.
Setting:
Rated Current
asynchronous motor.
Setting:
Rated Speed
plate of the asynchronous motor.
Setting:
Rated Cosinus Phi
asynchronous motor.
Setting:
Rated Frequency
indicated on the type plate of the asynchronous motor.
Setting:
06/05
06/05

Basic parameters

Menu branch PARA

28 - The brief instructions describe the parameters in control level 1.
1 ... 3
30 - The basic function of the control inputs and outputs as well as
110 -
sensor-less control with U/f characteristic for speed regulation
in a great number of standard applications
410 -
sensor-less, field-oriented control, for applications with a high
functionality and dynamics
34 - The factory settings of all parameters is restored or a fault
4444
Activate factory settings
123
Acknowledge fault message
369 – Setting of connected motor or transformer. The verification of the
0 -
Unknown
1 -
Asynchronous Three-phase asynchronous motor, squirrel cage
2 -
Synchronous
3 -
Reluctance
10 -
Transformer
370 - enter the voltage indicated on the type plate of the
60.0 V ... 800.0 V
371 - enter the rated current indicated on the type plate of the
0.01⋅I
... 10⋅o⋅I
FIN
372 – Enter the motor speed (at rated frequency) indicated on the type
-1
96 min
... 60000 min
374 – enter the cos (ϕ) value indicated on the type plate of the
0.01 ... 1.00
375 – Enter the rated frequency (at parameterized rated speed)
10.00 ... 1000.00
The motor is not a standard type.
Three-phase synchronous motor
Three-phase reluctance motor
Transformer with three primary windings
FIN
-1
47
47