at least 50mm above any carpet or
other floor covering. To achieve
this, the bottom of the flue spigot
opening must be at least 495mm
above the finished floor covering.
5.4.3 Check the flue pull with
closure plate fitted by applying a
lighted match or smoke match to the
flue spigot opening in the closure
plate and observe the smoke. If
there is a definite flow continue
with the installation. If not check the
fitting of the closure plate. The
fireplace flue pull check described
in section 5.2 should have
confirmed that the fireplace itself is
satisfactory.
Figure 8 Closure Plate for Wall Mounting
6 A P P L I A N C E I N S T A L L A T I O N

6.1 Installing To A Hearth

6.1.1 Place the fire centrally on the hearth
making sure that the spigot lines up with the
spigot hole in the closure plate. Gently slide
the appliance into place. The spigot must
enter the closure plate to a depth of at least
25mm.
6.1.2 Level the fire by loosening the lock
nuts and turning the levelling screws in the
feet up or down as required while they bear
on the hearth. When the fire is level and
square to the wall, retighten the lock nuts.

6.2 Wall Mounting

The fixing hole positions in relation to the
flue spigot opening are shown in figure 9.
Figure 9 Wall fixing holes
Mark these positions on the wall. The
Page 14