Models:
Evolve 952 / 1252
Installation guide
RHFE952ETRN / RHFE952ETRL
RHFE1252ETRN / RHFE1252ETRL

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai Evolve 952 Series

  • Page 1 Models: RHFE952ETRN / RHFE952ETRL RHFE1252ETRN / RHFE1252ETRL Evolve 952 / 1252 Installation guide...
  • Page 2 Important Appliance must be installed with a Rinnai approved flue system. This appliance must be installed in accordance with: - Manufacturer’s installation instructions - AS/NZS 5601 Gas Installations - AS/NZS 5263 Gas appliances standards For use with Natural Gas or Universal LPG as indicated on the appliance.
  • Page 3: Table Of Contents

    Contents Before you start ............4 Specification ............5 Dimensions ............6 Gas supply............7 Electrical supply............7 Wall penetration ............8 Framing dimensions ..........9 Clearances from combustibles ......10 TV installation ............12 Flueing options .............13 Evolve installation overview........14 Connection flue system ........15 Install heater into enclosure........16 Removing and replacing the glass panel .....17 Install burn media - log set ........18 Adding the granules..........20...
  • Page 4: Before You Start

    Failure to follow these instructions could cause a malfunction of the appliance. This could result in serious injury and/or property damage. Flue installation guide These instructions are to be used in conjunction with the Rinnai Arriva and Evolve flue installation guide supplied with the flue kits. Carton contents The components for the Evolve are supplied in three separate cartons (four if a mesh guard is purchased).
  • Page 5: Specification

    Specification Inbuilt power flued convection fan heater operated by a simple infra-red remote or by the Rinnai Wi-Fi app that allows full thermostatic control, as well as other features such as timers. Different burn media options are available. Specification summary...
  • Page 6: Dimensions

    Dimensions (mm) Evolve 952 1020 Evolve 1252 1255 1320 1000 | Evolve 952/1252 Installation Guide: 13115-E 05-19...
  • Page 7: Gas Supply

    The power cord passes through a slot in the back left hand corner of the appliance. Rinnai recommend the heater be plugged into a 230 V, 10 A earthed power point. The power point must not be above the heater. Alternatively the appliance can be direct wired if the power supply is to be concealed.
  • Page 8: Wall Penetration

    Wall penetration Direct flue wall penetration requirements Use the guide pictured to mark the penetration points for the gas supply and flue transition locations. Consideration must be given to the position of any studs, noggins or other components of the wall structure on both sides of the wall. Mark these measurements accurately as this is critical to a successful installation.
  • Page 9: Framing Dimensions

    Framing dimensions The main points governing location are flueing and warm air distribution. The Rinnai Evolve has an integrated zero clearance box that isolates the appliance from combustible materials. This means it can be installed directly into a decorative fireplace constructed from materials such as wood or plaster.
  • Page 10: Clearances From Combustibles

    Clearances from combustibles The clearances listed below, measured from the edge of the glass, are minimum clearances unless otherwise stated. While the heater is operating The appliance must not be installed where curtains or other combustible materials could come into contact with the fire. The 400 mm side clearance includes side walls.
  • Page 11 The below diagrams are to assist people who are determining the clearance area around the Evolve without having the unit on site. Evolve 952 1500 Minimum above fire Clearance Glass width Clearance Evolve 1252 1800 Minimum above fire 1000 Clearance Glass width Clearance Evolve 952/1252 Installation Guide: 13115-E 05-19 | 11...
  • Page 12: Tv Installation

    TV installation with the TV manufacturer—some have warranty conditions that state a TV is not to be installed above a fireplace. Rinnai does not accept any responsibility for damage to a TV resulting from the use of this information. 400 mm...
  • Page 13: Flueing Options

    90° bends, the maximum length can be 5.5 m. The adaption flue (EVOKIT03) is counted as one 90° bend. For lowest cost, optimal performance, ease of installation and servicing, Rinnai recommend direct flued installations are considered before all other options.
  • Page 14: Evolve Installation Overview

    Evolve installation overview 1. Construct a frame as per 2. Line wall—could also plaster 3. Complete the gas connection, enclosure dimensions on p. 9. at this stage. refer p.7. Electrical supply can also be completed at this point. 4. Connect the flue system. 5.
  • Page 15: Connect Flue System

    Connect flue system Consult the Rinnai Arriva and Evolve flue installation guide supplied with the Arriva/ Evolve flue kits for detailed flue installation instructions. For connection of the flue to the heater refer information below. Removing the pipe clamp, extension tube and exhaust pipe Before installing the heater into the enclosure the pipe clamp, telescopic extension tube, and exhaust pipe need to be removed so there is room to connect the flue system.
  • Page 16: Install Heater Into Enclosure

    Install heater into enclosure 1. Carefully move the heater into the enclosure, guiding the piping, flexible gas connection, and telescopic extension tube into the access openings and through the appliance. Ensure that the air hose is not in a position where it could get caught or crushed by the unit. 2.
  • Page 17: Removing And Replacing The Glass Panel

    Removing and replacing the glass panel Before the burn media can be installed into the combustion chamber, the glass panel needs to be removed. Remove the four retaining screws—two at the top and two at the bottom. When replacing tighten all four screws and then back off by quarter of a turn. If the glass panel is screwed too tight, the panel will bow and the spring release mechanism won’t work properly.
  • Page 18: Install Burn Media - Log Set

    Install burn media - log set The glass retainer will need to be removed before installing the log set and granules. Use extreme care when handling the log pieces, they are made from a fragile material and will damage easily. Use these instructions in conjunction with the burn media guide sheet, which is attached to the engine.
  • Page 19 The installation procedure for both models is the same. The only difference is the position of log eight and the addition of logs 9 and 10—the Evolve 1252 has an extra two logs. 1. Back left log 2. Back right log Align bottom locating holes with the locating pins at the Align bottom locating holes with the locating pins at the back of the burner—the log will sit up against the back...
  • Page 20: Adding The Granules

    10. Far RHS small log (1252 model only) 9. Far LHS small log (1252 model only) Fit the far small right hand log onto the two locator Fit the far small left hand log onto the two locator brackets. brackets. Adding the granules •...
  • Page 21: Install Burn Media - Stones

    Install burn media - stones The glass retainer will need to be removed before installing the stone set and granules. Use extreme care when handling the stones, they are made from a fragile material and will damage easily. Use these instructions in conjunction with the burn media guide sheet, which is attached to the engine.
  • Page 22 3. From the stone set box identify the six L1-L6 large 4. Place the six large grey stones on the middle and grey stones. back sections as shown below. 5. Start placing the remaining stones on the burner, 6. Place remaining grey stones on the back section of starting at the front—8 stones (identified with a dot).
  • Page 23 Evolve 1252 1. From the stone set box identify the five front grey 2. From the stone set box identify the eight L1-L8 cutout stones and place these on the burner brackets large grey stones and place them on the burner as at the front as shown below.
  • Page 24: Commissioning

    10 seconds. Once connected, guide the homeowner through the step by step instructions on the App. The Wi-Fi App is available on: • Google play > search Rinnai Fire App • App store > search Rinnai Fire App...
  • Page 25: Install The Inner And Outer Frame

    Install the inner and outer frames Installing the outer frame 1. Remove, but don’t discard, the two black screws installed in the lower bracket of the heater engine. 2. Position the outer frame close to the heater engine and connect the RJ45 plug into the socket on the inside top left of the heater.
  • Page 26: Test Operation And Lighting Sequence

    If the appliance cannot be made to perform correctly please contact Rinnai. Installation checklist and customer handover Complete the installation checklist in the customer operation guide, and make sure you leave the guide with the customer.
  • Page 27: Wiring Diagram

    Wiring diagram (part of commissioning) ON/OFF DISPLAY UNIT Wiring Diagram RHFE951/1250ETR Issue B CONTROL DISPLAY UNIT OH.TH 2 blk blk OH.TH 1 F (3A) gr/y R.TH AC 230-240V gr/y 6 5 4 4 3 2 1 3 2 1 bl w y bk bk bk bk y pl gy or y or bk br bl w...
  • Page 28 Rinnai.co.nz Tel: 0800 746 624 http://www.youtube.com/rinnainz Evolve 952 / 1252 installation guide 13115-E http://facebook.com.rinnainz...