Rinnai RHFE1000 Installation Manual page 14

Linear collection gas fireplaces
Hide thumbs Also See for RHFE1000:
Table of Contents

Advertisement

Linear 800 minimum framing dimensions (mm)
The framing dimensions have the studs offset. This is because the cavity needs to be
framed based on the centreline of the Linear glass, NOT the opening size.
IMPORTANT
Where there is a requirement for a symmetrical installation, the cavity size will need to
increase, refer diagram below.
845
770
Front face to
center of flue
Clearance (approx. 50 mm)
Shaded area denotes a clearance around the fire of approx. 50 mm.
On the RHS this is automatically achieved with the carry bar.
*
Minimum wallboard cutout, refer table on p.29
**
Maintain 25 mm clearance to combustibles for the first 500 mm of flue
All dimensions are assuming a 10 mm wallboard
Studs and joist are required directly below the support feet of the fire
Framing shown is 90 x 45 mm
Fire platform shown is 18 mm plywood
Allow room underneath the appliance for the gas supply to enter the fire cavity (min. 100 mm)
14 | Linear installation guide 13563-H 08-19
Glass centreline
1690 (for symmetrical cavity)
1365
845
1250
730
520
640
360
39 assumes
10 mm wallboard
Recommend that the lintel is left
until the fire is installed so min.
clearances can be maintained
403 mm assumes a 10 mm wallboard
on both sides of a double-sided unit.
415 mm is the min. for a single-sided
unit to maintain 50 mm clearance to
the back of the fire.
403