Edge finishing options
(applicable to any installation method)
Rinnai optional Outer Finishing
Trim, only suitable for the wall
lining is at least 1 mm set back
from the front face of the fire.
Wallboard cutout A
Cutout size B
With this bigger gap there is a risk that the
wallboard support panel and the Outer
Finishing Trim clips will be visible. Consider
this before utilising this method.
32 | Linear installation guide 13563-H 08-19
Adhesive is recommended in
place of screws as permanent
fixing across the top of the fire
A (1 : 1)
with optional Rinnai Outer Finishing Trim
Cutout size C
with 3 x 8 recess
A (1:1)
with wallboard edge finish
(no plaster or trim finish)
Wallboard support rail MUST be used for
combustible wallboard. The rail is
designed for wallboard thicknesses of 10,
13, and 20 mm, allowing for a 1 mm
setback for the Outer Finishing Trim or
plaster finish
Outer Finishing Trim
latch
A
Outer Finishing Trim
8
A (1:1)
with rebated wallboard edge finish
This method will produce a
closer fit to the fire but
does make the front edge
vulnerable to damage