Rinnai RDV3610ETR Operation Manual

Rinnai RDV3610ETR Operation Manual

Gas log flame fire
Table of Contents

Advertisement

SYMMETRY
®
*DV /RJ )ODPH )LUH
2SHUDWLRQ  ,QVWDOODWLRQ 0DQXDO
02'(/6 5'9(75
5'9(75
This appliance shall be installed in accordance with:
‡ 0DQXIDFWXUHU¶V ,QVWDOODWLRQ ,QVWUXFWLRQV
‡ &XUUHQW $6  $61=6 
‡ /RFDO 5HJXODWLRQV DQG 0XQLFLSDO %XLOGLQJ &RGHV
All Rinnai gas products
7KLV DSSOLDQFH PXVW EH LQVWDOOHG VHUYLFHG DQG UHSDLUHG E\ DQ $XWKRULVHG 3HUVRQ
are A.G.A. certified.

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai RDV3610ETR

  • Page 1 This appliance shall be installed in accordance with: ‡ 0DQXIDFWXUHU¶V ,QVWDOODWLRQ ,QVWUXFWLRQV ‡ &XUUHQW $6  $61=6  ‡ /RFDO 5HJXODWLRQV DQG 0XQLFLSDO %XLOGLQJ &RGHV All Rinnai gas products 7KLV DSSOLDQFH PXVW EH LQVWDOOHG VHUYLFHG DQG UHSDLUHG E\ DQ $XWKRULVHG 3HUVRQ are A.G.A. certified.
  • Page 2: Carton Contents

    INSTALLATION REQUIREMENTS This heater must be installed by an authorised person. The installation must conform to local regulations. The installation must also comply with the instructions supplied by Rinnai. Service and removal must be carried out by an authorised person.
  • Page 3: Table Of Contents

    POWER DISRUPTION ...................... 14 CARE AND MAINTENANCE..................15 GENERAL OPERATION CHARACTERISTICS ............... 15 SERVICE........................... 15 TROUBLE SHOOTING....................16 TROUBLE SHOOTING CHECKLIST ................16 ABNORMAL FLAME PATTERN..................16 TABLE OF CONTENTS - INSTALLATION ...............17 CONTACT INFORMATION ..................37 Rinnai Australia Operation & Installation Manual...
  • Page 4: Installation Record

    _____________________________________________________ Certificate of Compliance / Certification Number: ______________________________ Authorised Persons - Licence Number: _______________________________________ Installers Signature: _____________________________________________________ Installation Date: _____________________________________________________ APPLIANCE DETAILS Model Number: _____________________________________________________ Serial Number: _____________________________________________________ Installation Address: _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ Rinnai Australia Operation & Installation Manual...
  • Page 5: About Your Heater

    ABOUT YOUR HEATER RDV3610ETR / RDV3611ETR FRONT LAYOUT RDV3610ETR RDV3611ETR Typical places Note: Cladding support bracket fitted to RJ45 RDV3611ETR models Only! Connector Unit Features Mesh Dress Guard Manual Control Switch Panel Mesh Dress Guard Frame Lintel Stand-Off Brackets Surround...
  • Page 6: Safety

    • WARNING: This heater must not be used if the glass panel is damaged. • Minimum clearances during operation as follows: Non-combustible cladding MUST be provided for On heat sensitive RDV3610ETR surfaces provide installations. protective matting NOT required on to at least 750mm RDV3611ETR installations.
  • Page 7 • DO NOT modify this appliance. Modifying from original specifications may create a dangerous situation and will void your warranty. • Only the flue components specified by Rinnai must be used. Unpack the heater and check for damage. DO NOT INSTALL DAMAGED HEATER. If the heater is damaged, contact your supplier for advice.
  • Page 8 Snow Areas - in areas subject to heavy snowfall, keep snow clear of flue terminal at all times. Keep flammable materials, trees shrubs etc. away from the flue terminal. Rinnai Australia Operation & Installation Manual...
  • Page 9: Safety Devices

    However if AT LEAST 750 mm odours persist switch ‘OFF’ the appliance and contact Rinnai. SAFETY DEVICES • Over Heat Switches When the heater gets too hot during operation (for example when air outlet louvres are blocked) these devices turn the gas off automatically and allow the heater to restart when cooled down.
  • Page 10: About Your Controller

    ‘OK’ Button Setting Temperature with ‘SET’ display ‘PWR’ (Power) Button Transmit indicator ‘A/M’ Button Battery Low indicator ‘T’ (Time) Button Automatic mode indicator Setting ‘DOWN’ Button Program mode indicator ‘P’ (Program) Button Flame Indicator Rinnai Australia Operation & Installation Manual...
  • Page 11: Remote / Thermostat Control

    OFF due to room temperature being reached the symbol will modulate UP and DOWN. This is to indicate that the unit is still ON even though there are no flames visible in the appliance. Rinnai Australia Operation & Installation Manual...
  • Page 12: Remote Controller - Initial Set Up

    When changing batteries all settings will be lost and the controller will revert back to the 'Initial set -up screen'. Re-setting of time, date and programming will be NOTE necessary. Rinnai Australia Operation & Installation Manual...
  • Page 13: Wireless Controller Thermostat

    ‘UP’ increment hours, minutes, day or temperature ‘OK’, accepts the current function and advances to the next function, ‘DOWN’, decrement hours, minutes, day or temperature. P - (Program) Initiates the programming mode, press and hold for 2 seconds. Rinnai Australia Operation & Installation Manual...
  • Page 14: Customer Information - Operation

    As the air temperature in the room reaches the set temperature the flame and fan speed will reduce in unison accordingly. Rinnai Australia Operation & Installation Manual...
  • Page 15: How To Operate Your Heater

    P2’ The LCD will display ‘ to indicate Period 2 can now be set for the same day/s of the week. Repeat programming process for remaining periods. The controller will automatically turn ‘OFF’. Rinnai Australia Operation & Installation Manual...
  • Page 16 With the thermostat ‘OFF’, press the following sequence of buttons: ‘P’ > ‘T’ > ‘T’ ‘A/M’ to toggle between °C or °F. Change between manual, Press and release the ‘A/M’ button. automatic and flame modes Rinnai Australia Operation & Installation Manual...
  • Page 17: Manual Switch Mode

    'Manual Switch Mode' has been selected the heater will only operate by pressing the ‘Manual Switch’, once you have pressed the ‘Manual Switch’ the heater will not respond to the remote controller.” on page 14. Rinnai Australia Operation & Installation Manual...
  • Page 18: Care And Maintenance

    If the power supply cord or any other component of the heater are damaged, they must be replaced by Rinnai or a suitably qualified person. Any service or repair work should only be carried out by an authorised person. Rinnai has service and spare parts departments nationally. See back cover for contact details.
  • Page 19: Trouble Shooting

    Refer to page 14 for solution. ABNORMAL FLAME PATTERN Each Rinnai Flame Fire heater has a distinct flame pattern. The flame should look the same every time you start your heater, after an initial warm up period of approximately 15 minutes.
  • Page 20: Table Of Contents - Installation

    COMPLETE THE CLADDING ...................... 32 FIT THE SURROUND ........................33 REPLACE MESH DRESS GUARD & DRESS GUARD FRAME ASSEMBLY ......33 WIRING DIAGRAM....................34 CHECKLISTS ......................35 INSTALLATION AND COMMISSIONING CHECKLIST ..............35 FINAL CHECKLIST ........................35 NOTES ........................36 CONTACT INFORMATION ..................37 Rinnai Australia Installation Manual...
  • Page 21: Specifications

    SPECIFICATIONS GENERAL SPECIFICATIONS Model RDV3610ETR / RDV3611ETR Model Name ® Symmetry Gas Log Flame Fire Features Balanced Flue Inbuilt Gas Space Heater Burning log effect Glass front Convection Fan, top warm air outlet Wireless Remote control/thermostat, 7 day programmable timer...
  • Page 22: Dimensions

    DIMENSIONS 1090 MAIN BODY 1060 1006ID OUTER SURROUND 1110 Dimension Without Surround (mm) RDV3610ETR / RDV3611ETR Body Glass Front Cavity Width: 1050 1110 1100 Height: Depth: Dimension With Surround (mm) Body Glass Front *Depth Model RDV3610 RDV3611 RDV3610 RDV3611 RDV3610...
  • Page 23: Heater Location

    Co-Axial Flue components MUST be used. WARNING ® The Rinnai Symmetry MUST NOT be flued into ‘natural draft’ flue system or terminate into a chimney. GAS SUPPLY The gas supply terminates inside the heater at the front lower left hand side of the appliance.
  • Page 24: Enclosure Requirements

    • This heater is supplied with a power cord (length 1500 mm) and three pin plug. The power cord passes through the right hand side panel as shown. Rinnai recommend the heater be plugged into a 240V, 10A earthed power point. The power point must not be above the heater.
  • Page 25: Tv And Ornamentation Warning

    IDEA Check the manufacturers installation instructions for these items and ensure the recess is suitable. Rinnai does not take any responsibility for any damage occurring to any items installed above and in the vicinity of the heater. NOTE Rinnai Australia...
  • Page 26: Flue Installation

    Max 800 Min 300 horizontal flue installations no baffle plate is required Vertical Vertical Horizontal Flue Offset Flue Flue Installation Installation Installation Correct baffle must be used for vertical installations refer to page 28 for details. CAUTION Rinnai Australia Installation Manual...
  • Page 27: Types Of Flue Installation

    FLUE TERMINALS, ROOM-SEALED APPLIANCE TERMINALS AND OPENINGS OF OUTDOOR APPLIANCES * AS/NZS 5601: 2010 was current at the time of printing this manual, but may have been superseded. It is the installers responsibility to ensure that the NOTE current version of this standard is used. Rinnai Australia Installation Manual...
  • Page 28: Flue Information - Abey® Flue System

    Abey Order Code: DV990G 45° Elbow - 46DVA-E45 ® Abey Order Code: DV945G High Wind Terminal Cap - 46DVA-VCH ® Abey Order Code: DV991 Square Horizontal Terminal Cap - 46DVA-E48 (600mm) ® Abey Order Code: DV984 Rinnai Australia Installation Manual...
  • Page 29: Heater Installation

    26) by pulling in an outward direction along the bottom edge of the assembly, the assembly will swing out. Gently lift the entire assembly up-off and away from the locating fold along the top edge of the Glass Panel Assembly , and place it safely aside. Rinnai Australia Installation Manual...
  • Page 30: Insert And Fix The Appliance To The Frame Work

    See pages page 23, 23 & 24 for flue details. The flue system must be supported independently of the appliance. TYPICAL 4 PLACES Rinnai Australia Installation Manual...
  • Page 31: Connect Flue And Installing The Flue Restrictor

    4 .2 m e tre s & u p to 5 .4 m e tre s . 4 .2 m e tre s & u p to 5 .4 m e tre s. Rinnai Australia Installation Manual...
  • Page 32: Connect The Appliance To Consumer Gas Piping

    The log set must be installed in the precise order below. Ensure main burner is clean and free from particles and all packaging material. Piece 1. Log with rock attached. Rock end and left hand bottom edge into burner body locate this piece. Rinnai Australia Installation Manual...
  • Page 33: Replace The Glass Panel Assembly

    CHECKED AND SET IN ACCORDANCE WITH THESE INSTRUCTIONS WHEN THE WARNING APPLIANCE IS INSTALLED, OR AFTER THE REPLACEMENT OF ANY COMPONENT OR REASSEMBLY AFTER SERVICE. Step 9. CONNECT TO ELECTRICITY SUPPLY See page 21 for details. Rinnai Australia Installation Manual...
  • Page 34: Commission The Appliance

    10. During the initial burn in period, some smoke and smell may be emitted. The appliance should be run on the high position in a well ventilated room until these dissipate. 11. Check the flame pattern, see ‘Abnormal Flame Pattern’, section page 16 and page 33. Rinnai Australia Installation Manual...
  • Page 35: Replace Panels

    ‘Step 3 (5)’ page 26. Step 12. COMPLETE THE CLADDING Fit the remainder of the cladding. For RDV3610ETR ensure non-combustible material is used in the areas depicted in the drawings below.
  • Page 36: Fit The Surround

    Rinnai. ABNORMAL FLAME PATTERN ® The Rinnai Symmetry heater has a distinct flame pattern. This should look the same every time you start your heater, after an initial warm up period of approximately 20 minutes. Abnormal flame performance and/or pattern can indicate a problem with your heater, such as blocked gas injectors or the artificial logs/burn media have shifted from when the heater was first installed.
  • Page 37: Wiring Diagram

    WIRING DIAGRAM WIRING DIAGRAM AC 230V -240V 50 Hz (BROWN) (BROWN) (BLACK) (BLACK) (RED) (RED) (BROWN) (BROWN) (WHITE) (BLUE) (RED) (YELLOW) CABLE CAT 5 Rinnai Installation Manual...
  • Page 38: Checklists

    (To be completed by certified Gas Installer) 1. Appliance positioned in a suitable location (clearances, combustible clearances, mantels and surrounds etc). 2. Was a Rinnai approved flue system installed and tested in accordance with the instructions? 3. Gas pressure checked and set? 4.
  • Page 39: Notes

    NOTES Rinnai Installation Manual...
  • Page 40: Contact Information

    *Cost of a local call Higher from mobile or public phones. Fax: (03) 9271 6622 Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our Help Line.

This manual is also suitable for:

Rdv3611etrSymmetry rdv 3610

Table of Contents