Selecting Status Output Objects (Status Select) - Oval EL 2310-0BE Series Instructions Manual

Smart communication unit
Table of Contents

Advertisement

E-025-2-E

3.6.3.4 Selecting Status Output Objects (Status select)

① Click "Setup (S)" from the menu, and select "Status select" from the drop-down list of "Outputs",
then the following window (Fig. 45) will be displayed.
② Select for respective items.
Setting item
Overflow error
Hardware failure
Parameter alarm
Saturated alarm
Measurement signal alarm
Empty pipe alarm
Fixed output
Self diag in progress
NOTE: 1. When setting error and alarm as status output, click "ON".
2. Error output is valid only when "Status output func" is set to "Error Status".
3. Change the contact output when one or more items selected are in error.
4. For the detail of error, refer to "3.11.4 Error/Alarm, Status List".
③ Click "OK" after the setting is completed to display the message box (Fig. 46). Click "OK" here
to change the settings to the inputted values, and to reflect the changed setting values in the
flowmeter's output. If the flowmeter's output is used to control valves or other such parts as safety
protocol, change the control loop to manual control so that the control loop cannot be influenced
by the flowmeter's output.
2
Fig.45
Detail
Overflow error
Hardware failure error
Parameter alarm
Output saturation alarm (Analog, Pulse)
Measurement signal alarm
Measurement pipe empty detection alarm
Fixed output state (Analog, Pulse, Contact)
Self-diagnosis in process
Fig.46
Setting range
ON, OFF
ON, OFF
ON, OFF
ON, OFF
ON, OFF
ON, OFF
ON, OFF
ON, OFF