E-025-2-E
「Total overflow count」...The number of times counted when accumulated total flow value
「R-Total count」...Resettable flow totalizing counter
「R-Total flow」...Resettable total flow
「R-Total overflow count」...The number of times counted when resettable total flow returns
③ If there is a problem with the flowmeter transmitter, then an error message will be displayed in the
window under the process value measurement window. For details, refer to section 3.11.4 "Error/
Alarm, Status List".
④ To exit, click "Cancel".

3.5.2 Chart Display and Logging (Chart and Recording)

Chart display of flow rate and flow velocity as well as data logging can be carried out.
① Click "Chart and Recording" from the menu, and select "Active" , then a tool bar as shown in
Fig. 18 will appear underneath the menu.
② Click the
button on the tool bar or "Chart and Recording" - "Interval" of the menu, then the
window as shown in Fig. 19 appears, enabling setting of update interval of chart display and
logging interval.
Select the preferred interval from "0.2 Second" (only in RS485 communication), "0.5 Second" (only
in RS485 communication), "1 Second", "3 Seconds", "5 Seconds", "10 Seconds", "30 Seconds",
"1 Minute", "5 Minutes", "10 Minutes", and "1 Hour" and click "OK".

returns to "zero" by exceeding the maximum reading.
to "zero" by exceeding the maximum reading.
Fig.18
Fig.19