Oval EL 2310-0BE Series Instructions Manual page 24

Smart communication unit
Table of Contents

Advertisement

E-025-2-E
② Enter numeric values for respective items.
Setting item
Pulse operation
mode
Freq factor
Rate factor
Low cut
Pulse weight
③ Click "OK" after the setting is completed to display the message box (Fig. 40). Click "OK" here
to change the settings to the inputted values, and to reflect the changed setting values in the
flowmeter's output. If the flowmeter's output is used to control valves or other such parts as safety
protocol, change the control loop to manual control so that the control loop cannot be influenced
by the flowmeter's output.
④ The message box (Fig. 41) is displayed after changing the setting values. Click "OK" to complete
the setting process.
⑤ The window for setting item is displayed. To exit, click "Cancel".
2
Pulse output mode selection (Select from the right column.)
Frequency: Calculate with full-scale frequency and full-
scale flow.
Weight: Calculate with pulse weight.
Full-scale frequency of pulse output
Valid when pulse output mode is Frequency.
(Set value display area is highlighted.)
Full-scale flow rate of pulse output
Valid when pulse output mode is Frequency.
(Set value display area is highlighted.)
Low-cut value of pulse output
Low-cut value for preventing pulse output when flow rate
is near 0%.
Valid when pulse output mode is Frequency.
(Set value display area is highlighted.)
Pulse weight
Valid when pulse calculation mode is Weight.
(Set value display area is highlighted.)
Detail
Fig.40
Fig.41
Setting range
Frequency, Weight
1 to 10000
0.0 to 100.0%