Selecting the Rear Panel Remote Port Protocol and Baud Rate

The switcher can support either RS-232 or RS-422 serial communication protocol, and can
operate at 9600, 19200, 38400, and 115200 baud rates. The settings of these variables can
be viewed and changed from the front panel.
View and configure the serial communications settings of the switcher as follows:
1.
Select Serial Port Selection and Configuration mode: Simultaneously press and
hold the two top rightmost input buttons.
DMS 1600
DMS 3600
2.
Release the Input buttons.
3.
Change a value: Press and release the button that relates to the desired value.
Press and release the button(s) to configure the port as follows:
Baud rate:
Enter — 9600
View — 38400
Serial protocol:
Input 15 (17) — RS-232
The selected buttons blink and the others remain lit.
In this example, the port is set to RS-422 at 38400 baud.
ENTER
4.
Exit Serial Port Selection and Configuration mode: Press and release any output
button.
Press and release
an output button.
5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Press and hold the buttons.
2 seconds
4
15 16
Press and hold the buttons.
The flashing Control button indicates the baud rate as follows:
Enter — 9600
6
17 18
View — 38400
The flashing input button indicates the protocol as follows:
Input 15 (17) — RS-232
In this example, the port is set to RS-232 at 9600 baud.
Preset — 19200
Esc — 115200
Input 16 (18) — RS-422
C O N T R O L
4
VIEW
ESC
PRESET
All Control buttons and the Input 15 (17) and Input 16 (18)
buttons return to unlit or background illumination.
C O N T R O L
ENTER
PRESET
C O N T R O L
VIEW
ESC
ENTER
PRESET
All Control buttons light with
one flashing.
Release the buttons.
Preset — 19200
Esc — 115200
Input 16 (18) — RS-422
15 16
4
15 16
VIEW
ESC
DMS 1600 and DMS 3600 • Operation
4
15 16
Inputs 15 and 16 (DMS 1600) or
Inputs 17 and 18 (DMS 3600)
both light with one button flashing.