Software Operation via Ethernet

When a matrix switcher is connected to an Ethernet WAN or LAN, up to 200 users can
operate it, locally or remotely, using the Matrix Switchers Control Program (see
Connection" for installation details).
Connection to the switcher via the Ethernet is password protected. There are two levels of
password protection: administrator and user. Administrators have full access to all switching
capabilities and editing functions. Users can select inputs and outputs, recall presets, and
view all settings with the exception of passwords. If the same password or no password
is required for logging on, all personnel log on with administrator privileges. Fields and
functions that exceed user privileges are not selectable in the Matrix Switchers Control
Program when the operator is logged on as a user.
The IP Settings/Options window (see
viewing and, if connected via the RS-232 link or if logged on via the Ethernet port as an
administrator, editing settings unique to the Ethernet interface (see
Window" for more details).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
If the window does not open automatically, run Launch.exe from the DVD.
tab.
Software
Software Installation
C:\Program Files\Extron\Matrix_Switchers
\
Matrix Switchers:
For Windows 7, the folder is
Switchers
.
The DMS matrix switcher can support remote control via any of the following
three ports:
Rear panel LAN port — For IP control of the system via an Ethernet
LAN, via this RJ-45 connector from anywhere in the world.
Rear panel Remote RS-232/RS-422 port — The port can be configured
for either the RS-232 or RS-422 serial communication protocol and
operate at the 9600, 19200, 38400, or 115200 baud rate (see the
serial port parameters SIS commands
port).
Front panel Configuration port — A USB B port.
figure 28
(see figure 22).
Install
":
C:\Program Files (x86)\Extron\Matrix_
on page 61 to configure the
on page 68) provides a location for
"IP Settings/Options
DMS 1600 and DMS 3600 • Matrix Software
Extron
"Ethernet