Front Panel Configuration Port; Ethernet (Lan) Port; Ethernet Connection; Default Ip Addresses - Extron electronics DMS 1600 User Manual

Configurable digital video matrix switchers
Hide thumbs Also See for DMS 1600:
Table of Contents

Advertisement

Front Panel Configuration Port

A standard USB cable and the Extron DataViewer utility, version 2.0 or newer, can be used
for connection to the Configuration port. The USB cable, available at any local electronics
store, should be terminated on one end with a mini USB B male connector
NOTE:

Ethernet (LAN) Port

The rear panel Ethernet connector on the switcher can be connected to an Ethernet LAN
or WAN for SIS control of the switcher. Communications between the switcher and the
controlling device is via Telnet (a TCP socket using port 23). The TCP port can be changed
if necessary, via SIS. The SIS commands and the actions of the switcher are identical to the
commands and actions the switcher has when communicating with it via RS-232.

Ethernet Connection

The Ethernet cable can be terminated as a straight-through cable or a crossover cable and
must be properly terminated for your application (see figure 20).
Figure 20.

Default IP Addresses

To access the DMS matrix switcher via the LAN port, you need the Extron IP address, and
may need the subnet mask and the gateway address. If the IP address has been changed
to an address comprised of words and characters, you can determine the actual numeric
IP address using the ping utility (see
addresses have not been changed, the factory-specified defaults are:
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Before you use the DMS Configuration (USB) port for the first time, you need to
install and activate the USB driver on your computer. The simplest way to do this
is to install version 8.0 or newer of the Matrix Switchers Control Program and
then run the Found New Hardware Wizard (see
"Activating a USB Port for the First
Crossover cable — Direct connection between the computer and the
DMS matrix switcher
Patch (straight-through) cable — Connection of the DMS matrix switcher to an
Ethernet LAN
Crossover Cable
Pins:
12345678
End 1
Pin
Wire color
1
White-green
2
Green
3
White-orange
4
Blue
5
White-blue
6
Orange
7
White-brown
8
Brown
Insert Twisted
Pair Wires
T568A
RJ-45
A cable that is wired as T568A at one end
and T568B at the other (Tx and Rx pairs
Connector
reversed) is a "crossover" cable.
RJ-45 Ethernet Connector Pin Assignments
IP address:
192.168.254.254
Gateway address:
0.0.0.0
"Installing the
Time").
Straight-through Cable
End 2
End 1
Wire color
Pin
Wire color
White-orange
1
White-orange
Orange
2
Orange
White-green
3
White-green
Blue
4
Blue
White-blue
5
White-blue
Green
6
Green
White-brown
7
White-brown
Brown
8
Brown
T568B
T568B
A cable wired the same at both ends is
called a "straight-through" cable, because
no pin/pair assignments are swapped.
Connection" for more details). If the
"Ethernet
Subnet mask:
DHCP:
DMS 1600 and DMS 3600 • Programming Guide
Software" and
End 2
Wire color
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
T568B
255.255.0.0