Determining The Network Settings; Configuring The Network Settings - Comtrol DeviceMaster EIP Series Hardware Installation And Configuration Manual

Ethernet/ip
Table of Contents

Advertisement

RedBoot Procedures

Determining the Network Settings

If you are not sure what the network information is on a DeviceMaster, you can perform the following
procedure.
The default network settings are:
IP address: 192.168.250.250
Subnet mask: 255.255.0.0
Gateway address: 192.168.250.1
1. Establish communications with the DeviceMaster using the serial (Page 66) or telnet (Page 67) method.
2. At the RedBoot prompt, type ip.
The IP address, subnet mask, and IP gateway values will display.
Note: Optionally, you can install PortVision DX on a Windows system on the network and see the IP
information in the Device List pane.

Configuring the Network Settings

Use the following procedure to program the IP address using RedBoot.
1. Establish communications with the DeviceMaster using the serial (Page 66) or telnet (Page 67) method.
2. Enter ip [addr mask gateway] and press the Enter key to configure the IP address. Where:
addr = IP address you want to use
mask = matches you network subnet mask
gateway = assigned by your network administrator
Make sure that each value is separated by a space.
RedBoot>dis
Loading disabled
RedBoot> ip
RedBoot>
IP:
Mask:
Gateway: 192.168.0.254
RedBoot> reset
.. Resetting
3. Verify that RedBoot responds with your configured network information or reissue the command.
4. Type reset to reset the DeviceMaster, if you do not have any other related RedBoot tasks.
68 - RedBoot Procedures
192.168.11.152 255.255.0.0 192.168.0.254
192.168.11.152
255.255.00
DeviceMaster EIP | UP Hardware Installation and Configuration Guide: 2000633 Rev. C