RedBoot Procedures
Determining the Network Settings
Default Network
Settings
IP address:
192.168.250.250
Subnet mask:
255.255.0.0
Gateway address:
192.168.250.1
Configuring the Network Settings
44 - RedBoot Procedures
If you are not sure what the network information is on a DeviceMaster UP, you
can perform the following procedure.
1. Establish communications with the DeviceMaster UP using the serial (Page
42) or telnet (Page 43) method.
2. At the RedBoot prompt, type ip.
RedBoot>dis
Loading disabled
RedBoot> ip
IP:
192.168.250.250
Mask:
255.255.0.0
Gateway: 192.168.50.1
RedBoot>
The IP address, subnet mask, and IP gateway values will display.
Note: Optionally, you can install PortVision DX on a Windows system on the
network and see the IP information in the Device List pane.
Use the following procedure to program the IP address using RedBoot.
1. Establish communications with the DeviceMaster UP using the serial (Page
42) or telnet (Page 43) method.
2. Enter ip [addr mask gateway] and press the Enter key to configure the IP
address. Where:
addr = IP address you want to use
mask = matches you network subnet mask
gateway = assigned by your network administrator
Make sure that each value is separated by a space.
RedBoot>dis
Loading disabled
RedBoot> ip
192.168.11.152 255.255.0.0 192.168.0.254
RedBoot>
IP:
192.168.11.152
Mask:
255.255.00
Gateway: 192.168.0.254
RedBoot> reset
.. Resetting
3. Verify that RedBoot responds with your configured network information or
reissue the command.
4. Type reset to reset the DeviceMaster UP, if you do not have any other related
RedBoot tasks.
DeviceMaster UP 16-Port Hardware User Guide: 2000596 Rev. B