RedBoot Procedures

Establishing a Serial Connection

Use the following procedure to set up a serial connection with a terminal server program. You can use
HyperTerminal (Windows) or optionally, Test Terminal (WCom2), which can be accessed from PortVision DX
using Tools > Applications > Test Terminal (WCom2).
1. Connect a null-modem cable from an available COM port on your PC to Port 1 on the DeviceMaster.
Note: See
Connecting Serial Devices
2. Configure the terminal server program to the following values:
Bits per second = 57600
Data bits = 8
Parity = None
Stop bits = 1
Flow control = None
Note: If you do not disable Bootloader from loading (Steps 3 through 5) within the time-out period
(default is fifteen seconds), an application will be loaded from flash and started. If this happens,
repeat Steps 3 through 5. The #!DM command is the only case-sensitive command and must be in
uppercase.
3. Reset the DeviceMaster.
Note: Depending on the model, disconnect and reconnect the power cable (external power supply and no
power switch) or turn the power switch on and then off (internal power supply).
4. Immediately type #!DM and press Enter in the terminal program.
5. At the RedBoot> prompt, type dis, and press Enter.
6. Verify that loading has been disabled.
7. You can use the appropriate procedure listed on Page 65 or use the
71 to perform the desired task.
66 - RedBoot Procedures
on Page 35, if you need to build a null-modem cable.
#!DM
RedBoot>dis
Loading disabled
DeviceMaster EIP | UP Hardware Installation and Configuration Guide: 2000633 Rev. C