Extron electronics IP Link Series User Manual page 66

Power control interfaces
Table of Contents

Advertisement

Command
Remapping Port Designations
NOTE:
Duplicate port number assignments are not permitted, that is, Telnet and web cannot be the same. Entering duplicate port
assignments results in an E13 (invalid parameter) error message.
Set Telnet port map
24
Reset Telnet port map
24
Disable Telnet port map
24
View Telnet port map
Set web port map
24
Reset web port map
24
Disable web port map
24
View web port map
Set Direct Access port map
24
Disable Direct Access port map
View Direct Access port map
Remapping a port number (other than to reset it to the default 80 or 23, or to disable it by setting it to 0) must be to port
NOTE:
number 1024 or higher.
Event Control
Read event buffer memory
27
Write event buffer memor
y24,27
NOTE:
The response to the Write Event command is padded with leading zeros for
digits.
Read string from event buffer
memory
27
Write string to event buffer
memory
24,27
NOTES:
F must be capitalized in order for strings to be read and written to event buffer memory.
The response to the Write Event command is padded with leading zeros for
The Write String command requires a string beginning with
binary data (without an
X3%
KEY:
= Event number
X3^
= Event buffer
X3&
= Memory location
X3*
= Event data size
X3(
= Event data to write
X4$
= Number of bytes to read
X5$
= ASCII digits representing the numeric value of the data element read from the event buffer (leading zeros are
suppressed).
Start events
24,27
Stop events
24,27
Query number of events running
ASCII (Telnet)
(Host to Switcher)
E
port number MT
}
E
23MT
}
E
0MT
}
E
MT
}
E
port number MH
}
E
80MH
}
E
0MH
}
E
MH
}
E
2001MD
}
24
E
0MD
}
E MD}
E X3%,X3^,X3& X3* E}
X3*
E X3%,X3^,X3&,X3(
E X3%,X3^,X3&,X4$ FE}
E string*X3%,X3^,X3& FE}
E
).
0-99
0 = receive, 1 = user (absolute), 2 = User (relative), 3 = NVRAM
0 through maximum buffer size
b = bit, B = byte (8 bits), S = short (16 bits), L = long (32 bits). This parameter is case
sensitive.
Range = 1-127
E
1AE
}
E
0AE
}
E
AE
}
Verbose modes 2 and 3
URL Encoded (web)
(Host to Switcher)
W port number MT
|
W 23MT
|
W 0MT
|
W MT
|
W port number MH
|
W 80MH
|
W 0MH
|
W MH
|
W 2001MK|
W MD
|
WMD|
W X3% %2C X3^ %2C X3& X3* E}
E}
W X3% %2C X3^ %2C X3& %2C
X3%
W X3% %2C X3^ %2C X3& %2C
W X3( %2A X3% %2C X3^ %2C
X3%
and
E
. Strings returned by the device (read or write response) are
W 1AE
|
W 0AE
|
W AE
|
IPL T PC1 • SIS Programming and Control
Response
(Switcher to Host)
Pmt port number
]
Pmt 00023
]
Pmt 00000
]
port number
]
Pmh port number
]
Pmh 00080
]
Pmh 00000
]
port number
]
Pmd 02001
]
W 0MD
|
port number
]
X5$ ]
X3(
X3* E}
Evt
X3%
,
X3^
,
X3&
,
X3( ]
and
X3&
.
X3%
is 5 digits and
X3&
X4$
FE}
string
]
X3&
FE} Evt
X3%
,
X3^
,
X3&
,string
X3&
.
X3%
is 5 digits and
X3&
is 10 digits.
Ego
]
Est
]
nnnnn
]
(5-digit number)
Enm nnnnn
]
(5-digit number)
is 10
]
58

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip link ipl t pc1Ip link ipl t pc1i

Table of Contents